Difference between revisions of "Hardware"

From E12-11-009
Jump to navigationJump to search
 
(2 intermediate revisions by the same user not shown)
Line 4: Line 4:
  
 
== Polarimeter Documentation ==
 
== Polarimeter Documentation ==
* Calibration of a neutron polarimeter in the 0.2–1.1 GeV region [NIMA557 (2006) 585-593]: [[File:JLAB-PHY-06-461.pdf]]
+
[[Polarimeter Documentation | C-GEN Polarimeter Documentation]]
 
 
=== C-GEN Polarimeter Design / Documentation ===
 
* (18 Sept 2014) JT2go 3D model (based on working model in JLab CAD system; Contact: Paulo Medeiros)
 
** [https://userweb.jlab.org/~brads/c-gen/JT2GoSetup_tcm1023-85455.exe JT2go viewer (Windows)]
 
** [https://userweb.jlab.org/~brads/c-gen/HallC_layout_w_polarim-18Sep2014.jt Hall layout w/ mock-up of Magnets and "Plan B" detector using 160cm bars (JT file)]
 
** Images extracted from the above JT file:
 
<gallery mode="packed-hover" heights="140">
 
File:top-with_scale-18Sep2014.jpg |''[[File:top-with_scale-18Sep2014.pdf]]''
 
File:top-with_scale_midplane_cut-18Sep2014.jpg |''[[File:top-with_scale_midplane_cut-18Sep2014.pdf]]''
 
File:side-isometric-18Sep2014.jpg |''[[File:side-isometric-18Sep2014.pdf]]''
 
File:side_isometric-midplane_cut-18Sep2014.jpg |''[[File:side_isometric-midplane_cut-18Sep2014.pdf]]''
 
File:side-isometric_no_mag1-18Sep2014.jpg |''[[File:side-isometric_no_mag1-18Sep2014.pdf]]''
 
File:side_isometric_no_mag2-18Sep2014.jpg |''[[File:side_isometric_no_mag2-18Sep2014.pdf]]''
 
File:top_isometric_midplane_cut-18Sep2014.jpg |''[[File:top_isometric_midplane_cut-18Sep2014.pdf]]''
 
File:top_zoomed-out-18Sep2014.jpg |''[[File:top_zoomed-out-18Sep2014.pdf]]''
 
</gallery>
 
 
 
[[File:side-isometric-18Sep2014-big.gif|upright=2.0|thumb|alt=C-GEn "Plan B" Polarimeter]]
 
=== Possible scintillator hardware ===
 
==== The "Plan B" design requires: ====
 
* Total:  136x  10 cm  x 10 cm    "thick" bars
 
108  10 cm  x 10 cm x 160 cm  E counters (top + bottom)
 
  28  10 cm  x 10 cm x 160 cm  analyzer bars
 
* Total:  80x    1 cm  x 10 cm    "thin" bars
 
  52    1 cm  x 10 cm x 160 cm  dE  (top + bottom)
 
  28    1 cm  x 10 cm x 160 cm  analyzer vetos
 
 
 
* All bars are double-ended readout.
 
----
 
 
 
==== Existing Scintillator Bars ====
 
===== BLAST bars  (some from PSI LADS detector) =====
 
  Ohio walls: 16x      10 cm x 22.5 cm    x 400 cm
 
  LADS15:    28x      15 cm x 14.5 cm(*) x 160 cm
 
  LADS20:·    28x      20 cm x  9.8 cm(*) x 160 cm
 
  (*) bars are trapezoidal shaped; this is mid-point thickness
 
* Availability:  '''Yes'''  (needs to be shipped to Kent St/JLab)
 
* Location:      BATES
 
* Contact:        Michael Kohl
 
* References:      [[Media:Hasell_NIMA603_2009_247_BLAST.pdf |NIM A 603 (2009) 247–262]] (BLAST detector), [[Media:Alteholz_NIMA373_1996_374.pdf |NIM A 373 ( 1996) 374-38]] (PSI LADS reference)
 
* Notes:
 
** Bars would need to be cut and polished
 
** The LADS bars are trapezoidal; they can be stacked into planes by alternating the 'wedge' direction
 
** Needs new PMTs
 
 
 
 
 
===== "BigBite" HAND =====
 
  32x  10 cm x 10  cm  x  100 cm
 
  32x  10 cm x 12.5cm  x  100 cm
 
  12x  10 cm x 15  cm  x  100 cm
 
  12x  15 cm x 25  cm  x  100 cm
 
  32x    2 cm x 11  cm  x  100 cm
 
* Availability:    '''Yes'''
 
* Location:      JLab ESB
 
* Contact:        Doug Higinbotham
 
* Reference:  [http://hallaweb.jlab.org/staff/doug/outreach/students/Summer2009/Dominik-Wermus-Paper.pdf Wermus Tech Note]
 
* Notes:
 
** These are available now
 
** Will likely need to replace most of the (3") PMTs
 
 
 
 
 
===== GEn E02-013 BigHAND neutron array =====
 
UVa:      100x    10 cm x 10 cm x 160 cm
 
Glasgow:  24x    10 cm x 20 cm x 180 cm
 
CMU:      120x      5 cm x 15 cm x 180 cm
 
* Availability:    '''???''' (there are plans to use the BigHAND array in Hall A)
 
* Location:  Bldg 64 (tent at NE corner of Accel area)
 
* Contacts:  Mixed:  UVa (Donal Day), CMU (G. Franklin?), Glasgow (J. Annand); Bogdan, Albert (JLab)
 
* Reference: [http://hallaweb.jlab.org/experiment/E02-013/ND_Geometry.pdf BigHAND Geometry]], [http://hallaweb.jlab.org/experiment/E02-013/docs.html General Documentation]]
 
* Notes:
 
** These are still stored in the BigHAND cartridges in Bldg 64
 
** PMT status TBD
 
** At our 2013 collaboration meeting Donal mentioned the UVa bars are still available and are still under UVa ownership.
 
 
 
 
 
===== Existing Material at Kent State =====
 
8x  10 cm x 51 cm x 100 cm  (actual dimensions: 4" x 20" x 40")
 
3x  10 cm x 25 cm x 100 cm  (actual dimensions: 4" x 10" x 40")
 
* Availability:    '''Yes'''
 
* Location:  Kent State
 
* Contacts:  Bryon Anderson
 
* Reference:
 
* Notes:
 
** Needs cutting and polishing
 
** PMTs needed
 
 
 
 
 
===== Existing bars within Collaboration =====
 
SUNO    (Mostafa Elaasar):  ??x  1 cm x 10 cm x 100 cm
 
La Tech (Steve Wells):      ??x  10 cm x 10 cm x 100 cm
 
* Availability:    '''Yes'''
 
* Notes:
 
** Purchased as test bars with an eye to incorporation into full polarimeter
 
** PMTs are included
 

Latest revision as of 17:52, 29 September 2014

Magnet Documentation

Polarimeter Documentation

C-GEN Polarimeter Documentation