Line 35: | Line 35: | ||
const FADC_ADDR = 0x680000 # 12 bit fADC MOTT - Slot 7 | const FADC_ADDR = 0x680000 # 12 bit fADC MOTT - Slot 7 | ||
const FADCMODE = 1 (Mott_Sample) | const FADCMODE = 1 (Mott_Sample) | ||
− | const FADCMODE = | + | const FADCMODE = 3 (Mott_SemiInt) |
const FADCSLOT_Mott = 7 | const FADCSLOT_Mott = 7 | ||
const TRSPLIT = 0xeb13 # Address of fADC Signal Distribution Module | const TRSPLIT = 0xeb13 # Address of fADC Signal Distribution Module | ||
Line 44: | Line 44: | ||
const FADC_ADDR = 0xed0000 # 12 bit fADC Int - Slot 10 | const FADC_ADDR = 0xed0000 # 12 bit fADC Int - Slot 10 | ||
− | const FADCMODE = 3 | + | const FADCMODE = 3 (Int_Int, special) |
const FADCSLOT_PEPPo3 = 10 | const FADCSLOT_PEPPo3 = 10 | ||
const TRSPLIT = 0xea13 # Address of fADC Signal Distribution Module | const TRSPLIT = 0xea13 # Address of fADC Signal Distribution Module |
Revision as of 09:12, 30 October 2013
Summary of CODA Configurations
Name | Readout | Output | Trigger |
Scalers | Scaler S1 (helicity gated), S2 (un-gated) | Scalers_%d.dat | Delayed nT_Settle |
Mott_Sample | Mott FADC, S1, S2, TDC | Mott_Sample_%d.dat | Mott Detector |
Mott_SemiInt | Mott FADC, S1, S2, TDC | Mott_SemiInt_%d.dat | Mott Detector |
FADC_Int | INT FADC, S1, S2 | FADC_Int_%d.dat | nT_Settle |
Mott FADC
const FADC_ADDR = 0x680000 # 12 bit fADC MOTT - Slot 7 const FADCMODE = 1 (Mott_Sample) const FADCMODE = 3 (Mott_SemiInt) const FADCSLOT_Mott = 7 const TRSPLIT = 0xeb13 # Address of fADC Signal Distribution Module
INT FADC
const FADC_ADDR = 0xed0000 # 12 bit fADC Int - Slot 10 const FADCMODE = 3 (Int_Int, special) const FADCSLOT_PEPPo3 = 10 const TRSPLIT = 0xea13 # Address of fADC Signal Distribution Module
TDC
CAEN v775 const int V775_ADD = 0x1190
S1
S2
TID
A24 Address for TID Module (0x100000 for VME Slot 2) const TRIG_ADDR=0x100000