Difference between revisions of "GTS meeting 10 02 17"
Jump to navigation
Jump to search
(One intermediate revision by the same user not shown) | |||
Line 2: | Line 2: | ||
− | * Laser heating and QE decay | + | * Why is photocathode lifetime limited (100 - 300 C)? |
+ | # Laser heating and QE decay | ||
+ | # Laser size too small? | ||
+ | |||
+ | |||
+ | * Remaining tasks before shutdown on Wednesday Oct. 4, 2017: | ||
+ | # Measure lifetime with a larger laser size (~rms=0.5 mm) | ||
+ | # Measure lifetime for: 0 A, 50 A, 100 A, 150 A, 200 A, 300 A, 400 A (Gun HV=300 kV, I=3.0 mA) | ||
+ | # Lifetime vs biased anode | ||
* Jay's magnetic field model of Radiabeam steerers and Gun Solenoid: [[media:GTS_magnetic_model_Jay_Oct2017.pdf]] | * Jay's magnetic field model of Radiabeam steerers and Gun Solenoid: [[media:GTS_magnetic_model_Jay_Oct2017.pdf]] |
Latest revision as of 09:08, 2 October 2017
- High current runs
- Why is photocathode lifetime limited (100 - 300 C)?
- Laser heating and QE decay
- Laser size too small?
- Remaining tasks before shutdown on Wednesday Oct. 4, 2017:
- Measure lifetime with a larger laser size (~rms=0.5 mm)
- Measure lifetime for: 0 A, 50 A, 100 A, 150 A, 200 A, 300 A, 400 A (Gun HV=300 kV, I=3.0 mA)
- Lifetime vs biased anode
- Jay's magnetic field model of Radiabeam steerers and Gun Solenoid: media:GTS_magnetic_model_Jay_Oct2017.pdf