Difference between revisions of "GTS meeting 9 17 18"

From Ciswikidb
Jump to navigation Jump to search
(Created page with "* RCD has authorized running at these levels without RadCon support: ** 100 kV up to 26 mA ** 200 kV up to 15 mA ** 300 kV up to 4.5 mA * If voltage or current is increased...")
 
 
Line 6: Line 6:
  
 
* If voltage or current is increased beyond above, RadCon must be notified, and present for running.
 
* If voltage or current is increased beyond above, RadCon must be notified, and present for running.
 +
 +
 +
* Remaining high current runs (1.8 W):
 +
# 100 kV, '''''26 mA'''''; Gun Solenoid at 200 Amps
 +
# 200 kV, 15 mA: '''''Gun Solenoid at 400 Amps'''''

Latest revision as of 09:49, 17 September 2018

  • RCD has authorized running at these levels without RadCon support:
    • 100 kV up to 26 mA
    • 200 kV up to 15 mA
    • 300 kV up to 4.5 mA


  • If voltage or current is increased beyond above, RadCon must be notified, and present for running.


  • Remaining high current runs (1.8 W):
  1. 100 kV, 26 mA; Gun Solenoid at 200 Amps
  2. 200 kV, 15 mA: Gun Solenoid at 400 Amps