- RCD has authorized running at these levels without RadCon support:
- 100 kV up to 26 mA
- 200 kV up to 15 mA
- 300 kV up to 4.5 mA
- If voltage or current is increased beyond above, RadCon must be notified, and present for running.
- Remaining high current runs (1.8 W):
- 100 kV, 26 mA; Gun Solenoid at 200 Amps
- 200 kV, 15 mA: Gun Solenoid at 400 Amps