Difference between revisions of "GBS - March 8, 2019"
Jump to navigation
Jump to search
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
− | |||
==Questions to Answer and Plots to Make== | ==Questions to Answer and Plots to Make== | ||
;Ion/Secondary Production | ;Ion/Secondary Production | ||
Line 19: | Line 18: | ||
*...if yes, then what is this limit, pA, nA, is FE enough, or if NO is there a dependence on beam current? | *...if yes, then what is this limit, pA, nA, is FE enough, or if NO is there a dependence on beam current? | ||
− | ;Diagnostics and Measurements | + | ;Diagnostics and Measurements Plans for the PGUN and TGUN beam ilnes |
*[[media:190308_GTS_Plan.pdf]] | *[[media:190308_GTS_Plan.pdf]] | ||
+ | |||
+ | [[Ghost Beam Studies | Return to Ghost Beam Studies]] |
Latest revision as of 13:04, 10 March 2019
Questions to Answer and Plots to Make
- Ion/Secondary Production
- Is production rate proportional to (current, pressure)? does it scale with ionization cross-section beam energy?
- Is trap density proportional to production rate, i.e. scale w/ (current, pressure, time)? similarly, for beam energy?
- Magnetic Trap Threshold
- Does trap density depend upon the magnetized solenoid current? if yes, what is the dependence on current?
- Does the min magnetizing current to sustain a trap, depend on the max magnetizing current?
- or is it a fixed threshold, independent of beam energy, current, pressure, time, etc?
- Role of Anode Bias
- Is the anode bias essential for magnetic trapping of ions?
- ... or rather, what impact does the anode bias have on the trap efficiency or trap density?
- Role of the Electron Beam
- Must the primary electron beam be run? if FE is present, is this sufficient? in lack of photo- or FE- beam, is there any notable ion production?
- Can trap density co-exist w/ electron beam? is there a beam clearing effect, i.e. can trap density remain only when beam is "OFF"
- ...if yes, then what is this limit, pA, nA, is FE enough, or if NO is there a dependence on beam current?
- Diagnostics and Measurements Plans for the PGUN and TGUN beam ilnes