*[[:File:Dataimputbeam3.txt | 25000 electron initial distribution text file]] - 25000 electrons, uniform transverse distribution, 5mm radius, starting at z=0mm (pancake distribution)
 
*[[:File:Dataimputbeam3.txt | 25000 electron initial distribution text file]] - 25000 electrons, uniform transverse distribution, 5mm radius, starting at z=0mm (pancake distribution)
  
*[[:File:GaussianInputDistribution_2pC_50ps_0mmStart_NoSC.txt | 5000 electron bunch text file - start @ z=0mm]] - 5000 electron bunch, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), starting at z=0mm, 2pC bunch charge, 50ps bunch length, space charge OFF
+
*[[:File:GaussianInputDistribution_2pC_50ps_0mmStart_NoSC.txt | 5000 electron bunch text file - start @ z=0mm]] - 5000 electrons, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), Gaussian longitudinal distribution (50ps RMS bunch length, cutoff at 50ps), starting at z=0mm, 2pC bunch charge, space charge OFF
*[[:File:GaussianInputDistribution_2pC_50ps_0mmStart_SC.txt | 5000 electron bunch text file - start @ z=0mm with space charge]] - 5000 electron bunch, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), starting at z=0mm, 2pC bunch charge, 50ps bunch length, space charge ON
+
*[[:File:GaussianInputDistribution_2pC_50ps_0mmStart_SC.txt | 5000 electron bunch text file - start @ z=0mm with space charge]] - 5000 electrons, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), Gaussian longitudinal distribution (50ps RMS bunch length, cutoff at 50ps), starting at z=0mm, 2pC bunch charge, space charge ON
*[[:File:GaussianInputDistribution_2pC_50ps_135mmStart_NoSC.txt | 5000 electron bunch text file - start @ z=135mm]] - 5000 electron bunch, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), starting at z=135mm, 2pC bunch charge, 50ps bunch length, space charge OFF
+
*[[:File:GaussianInputDistribution_2pC_50ps_135mmStart_NoSC.txt | 5000 electron bunch text file - start @ z=135mm]] - 5000 electrons, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), Gaussian longitudinal distribution (50ps RMS bunch length, cutoff at 50ps),starting at z=135mm, 2pC bunch charge, space charge OFF
*[[:File:GaussianInputDistribution_2pC_50ps_135mmStart_SC.txt | 5000 electron bunch text file - start @ z=135mm with space charge]] - 5000 electron bunch, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), starting at z=135mm, 2pC bunch charge, 50ps bunch length, space charge ON
+
*[[:File:GaussianInputDistribution_2pC_50ps_135mmStart_SC.txt | 5000 electron bunch text file - start @ z=135mm with space charge]] - 5000 electrons, Gaussian transverse distribution (1mm RMS, cutoff at 3mm), Gaussian longitudinal distribution (50ps RMS bunch length, cutoff at 50ps),starting at z=135mm, 2pC bunch charge, space charge ON
  
  

Revision as of 22:32, 9 January 2020

Initial Distribution


Plots

Return to Ionization Effects