# <u>Gun Voltage</u>: 100 kV
 
# <u>Gun Voltage</u>: 100 kV
# <u>Gun Solenoid Current</u>:  
+
# <u>Gun Solenoid Current</u>: 150 A. Experiments varied the current between 30 A and 150 A
 +
# <u>Anode Voltage</u>: 1 kV (961 V). Experiments varied the anode bias voltage between 388 V and 961 V
 +
# <u>Beam Current</u>: 100-500 uA
 +
# <u>Gun Vacuum Levels</u>: Usually > 1e-9 A ion pump current at the gun
  
 
== Proposed Parameters ==
 
== Proposed Parameters ==

Revision as of 12:14, 19 November 2020

Info on proposed steel shield experiments using the T-Gun at GTS

Previous Parameters

  1. Gun Voltage: 100 kV
  2. Gun Solenoid Current: 150 A. Experiments varied the current between 30 A and 150 A
  3. Anode Voltage: 1 kV (961 V). Experiments varied the anode bias voltage between 388 V and 961 V
  4. Beam Current: 100-500 uA
  5. Gun Vacuum Levels: Usually > 1e-9 A ion pump current at the gun

Proposed Parameters

  1. Gun Voltage: 90 kV

Experimental Procedure

Relevant Calculations/Tech Notes/Useful Links


Return to Ghost Beam Studies