Difference between revisions of "2020 Steel Shield Experiments at GTS"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
# <u>Gun Voltage</u>: 100 kV | # <u>Gun Voltage</u>: 100 kV | ||
− | # <u>Gun Solenoid Current</u>: | + | # <u>Gun Solenoid Current</u>: 150 A. Experiments varied the current between 30 A and 150 A |
+ | # <u>Anode Voltage</u>: 1 kV (961 V). Experiments varied the anode bias voltage between 388 V and 961 V | ||
+ | # <u>Beam Current</u>: 100-500 uA | ||
+ | # <u>Gun Vacuum Levels</u>: Usually > 1e-9 A ion pump current at the gun | ||
== Proposed Parameters == | == Proposed Parameters == |
Revision as of 12:14, 19 November 2020
Info on proposed steel shield experiments using the T-Gun at GTS
Previous Parameters
- Gun Voltage: 100 kV
- Gun Solenoid Current: 150 A. Experiments varied the current between 30 A and 150 A
- Anode Voltage: 1 kV (961 V). Experiments varied the anode bias voltage between 388 V and 961 V
- Beam Current: 100-500 uA
- Gun Vacuum Levels: Usually > 1e-9 A ion pump current at the gun
Proposed Parameters
- Gun Voltage: 90 kV