Difference between revisions of "2020 Steel Shield Experiments at GTS"
Jump to navigation
Jump to search
Line 9: | Line 9: | ||
# <u>Gun Vacuum Levels</u>: Usually > 1e-9 A ion pump current at the gun | # <u>Gun Vacuum Levels</u>: Usually > 1e-9 A ion pump current at the gun | ||
− | == Proposed Parameters == | + | == Proposed Parameters and Predicted Results == |
# <u>Gun Voltage</u>: 90 kV | # <u>Gun Voltage</u>: 90 kV |
Revision as of 12:19, 19 November 2020
Info on proposed steel shield experiments using the T-Gun at GTS
Previous Parameters
- Gun Voltage: 100 kV
- Gun Solenoid Current: 150 A. Experiments varied the current between 30 A and 150 A
- Anode Voltage: 1 kV (961 V). Experiments varied the anode bias voltage between 388 V and 961 V
- Beam Current: 100-500 uA
- Gun Vacuum Levels: Usually > 1e-9 A ion pump current at the gun
Proposed Parameters and Predicted Results
- Gun Voltage: 90 kV