Difference between revisions of "2020 Steel Shield Experiments at GTS"
Jump to navigation
Jump to search
Line 19: | Line 19: | ||
== Experimental Procedure == | == Experimental Procedure == | ||
− | # Install photo-diode | + | # Install Newport silicon photo-diode with power meter on angled lens (photodiode info: [https://www.newport.com/p/818-SL--DB] ) |
== Predicted Results == | == Predicted Results == |
Revision as of 16:16, 19 November 2020
Info on proposed steel shield experiments using the T-Gun at GTS
Previous Parameters
- Gun Voltage: 100 kV
- Gun Solenoid Current: 150 A. Experiments varied the current between 30 A and 150 A
- Anode Voltage: 1 kV (961 V). Experiments varied the anode bias voltage between 388 V and 961 V
- Beam Current: 100-500 uA
- Gun Vacuum Levels: Usually > 1e-9 A ion pump current at the gun
Proposed Parameters
- Gun Voltage: 90 kV (should be fine for experiment purposes)
- Gun Solenoid Current: 150 A
- Anode Voltage: 1 kV
- Beam Current: 500 uA or higher (to ensure sufficient measured intensity from recombining ions)
- Gun Vacuum Levels: Higher pressure -> higher ion production rate -> higher number of recombining ions.
Experimental Procedure
- Install Newport silicon photo-diode with power meter on angled lens (photodiode info: [1] )