== Take home ==
 
== Take home ==
 
* Current picture of ITVM703 to make sure width/height is still what it was
 
* Current picture of ITVM703 to make sure width/height is still what it was
 +
** Seems close. Picture on FTP server.
 
* Why is the y axis of the viewer inverted when steering with 701V? Or is it both the harp and the magnet that are inverted? Check with 702...
 
* Why is the y axis of the viewer inverted when steering with 701V? Or is it both the harp and the magnet that are inverted? Check with 702...
 +
** The magnet is inverted. OPS-PR'd.
 
* UED s coordinate of MDLM601
 
* UED s coordinate of MDLM601
 +
** 18.4718
 
* 703 harp file, e.g., /cs/data/harpData/IHAM703/IHAM703.10262021_18:....
 
* 703 harp file, e.g., /cs/data/harpData/IHAM703/IHAM703.10262021_18:....
 
* using 703 harp, measure momentum spread vs. something interesting, e.g., buncher amplitude
 
* using 703 harp, measure momentum spread vs. something interesting, e.g., buncher amplitude
 
* '''Ascertain harp data calibration without factor sqrt(2)'''. How to test this?
 
* '''Ascertain harp data calibration without factor sqrt(2)'''. How to test this?
 
* Survey 700 line with tape measure
 
* Survey 700 line with tape measure
 +
** From center of dipole:
 +
** 701HV at 0.558 m (1ft 10in)
 +
** 702HV at 1.495 m (4ft 11in)
 +
** 703 harp at 2.153 m (7ft 1in)
 +
** 703 viewer at 2.280 m (7ft 6in)

Revision as of 22:46, 29 November 2021

Random

  • Harp axis calibration does not matter: It only changes the measured emittance but not alpha/beta, and its effect does not depend on the quad in use.
  • Adding reasonable quadrupole moments to correctors is not enough to explain the inconsistency. It would need an extra quad with K1 ~ 5.
  • At dp/p = 1e-3 (which is higher than what we observe unless the measurement is flawed), seeing significant inconsistencies in the quad scans needs a dispersion of many cm. In y, the only dispersion in this part of the lattice should come from the earth's field; this gives about 8 mm at the harp, much too low to see anything.

For future study

  • Provided the BPMs work at all, we can use the 701 and 702 BPMs to better measure the momentum jitter. The CW waveforms give time-domain data in 900-microsecond-long windows with 16384 samples each, i.e., ~ 18 kHz sampling rate, 9 kHz analog bandwidth. More than enough to see all peaks, maybe even a little much to resolve them well. The only problem is, we can only run 100 nanoamps CW into that line. See if that's enough to see anything.

Take home

  • Current picture of ITVM703 to make sure width/height is still what it was
    • Seems close. Picture on FTP server.
  • Why is the y axis of the viewer inverted when steering with 701V? Or is it both the harp and the magnet that are inverted? Check with 702...
    • The magnet is inverted. OPS-PR'd.
  • UED s coordinate of MDLM601
    • 18.4718
  • 703 harp file, e.g., /cs/data/harpData/IHAM703/IHAM703.10262021_18:....
  • using 703 harp, measure momentum spread vs. something interesting, e.g., buncher amplitude
  • Ascertain harp data calibration without factor sqrt(2). How to test this?
  • Survey 700 line with tape measure
    • From center of dipole:
    • 701HV at 0.558 m (1ft 10in)
    • 702HV at 1.495 m (4ft 11in)
    • 703 harp at 2.153 m (7ft 1in)
    • 703 viewer at 2.280 m (7ft 6in)