Difference between revisions of "Run1 - January 2015"

From Ciswikidb
Jump to navigation Jump to search
Line 20: Line 20:
 
  Elastic events counted for IHWP=IN/OUT
 
  Elastic events counted for IHWP=IN/OUT
  
= Prep Work (through Tuesday Jan 13)
+
= Prep Work (through Tuesday Jan 13) =
 
#Make a photocathode – SL5247-1 made
 
#Make a photocathode – SL5247-1 made
 
#Test IHA2D00 – wires & stroke good, but data file odd vs. others
 
#Test IHA2D00 – wires & stroke good, but data file odd vs. others
Line 31: Line 31:
 
#Build qsUtility config file –documented below
 
#Build qsUtility config file –documented below
  
Version 4 Notes
+
= Injector Setup and Mott Checkout (Wed Jan 14 - Fri Jan 16) =
* Word [[media:Mott_Run1_v4.docx]]
+
#Restore beam to FC2 @ 6.3 MeV/c
* PDF [[media:Mott_Run1_v4.pdf]]
+
#Mott test: DAQ FADC/TDC synchronization
 +
#Mott test: event separation and transmission at 62MHz acceptable
 +
#Quad center BPMs for momentum measurement
 +
#Test harp IHA2D00 if ready for energy spread measurement
 +
#Scale cryounit for p=5.487 MeV/c and minimize energy spread
 +
#Precisely measure beam momentum
 +
#Measure beam emittance
 +
#Measure energy spread
 +
#Calibrate BCM to FC2

Revision as of 13:47, 12 January 2015

This page will be used for the Run 1 experiment and analysis

Shift Schedule

140112 shifts.png

Shift Worker Duties

Beam Driver
Beam setup: gun + laser + spin + beam to Mott
BCM & target motion FSDs enabled 
Vacuum levels reasonable
Magnet and RF setup saved
PITA adjusted for IHWP IN/OUT
DAQ Driver
Start/Stop DAQ entering correct run information
Monitor event rates and maintain dead time <5%
Coordinate run start/stop with Beam and Analysis Drivers
Analysis Driver
Runs decoded, analyzed and promptly inspected
Run # and information logged onto run sheets
Elastic events counted for IHWP=IN/OUT

Prep Work (through Tuesday Jan 13)

  1. Make a photocathode – SL5247-1 made
  2. Test IHA2D00 – wires & stroke good, but data file odd vs. others
  3. Hi-Pot IP – FE’r potted, but high again, vac readback not good
  4. CHL 2K cooldown – maybe early, Monday Jan 12th
  5. Install laser – Tue or Wed
  6. Test laser RF trigger – after laser installed (1V, 10ns @ RF)
  7. Verify beam line layout –documented below
  8. Build elegant deck – working
  9. Build qsUtility config file –documented below

Injector Setup and Mott Checkout (Wed Jan 14 - Fri Jan 16)

  1. Restore beam to FC2 @ 6.3 MeV/c
  2. Mott test: DAQ FADC/TDC synchronization
  3. Mott test: event separation and transmission at 62MHz acceptable
  4. Quad center BPMs for momentum measurement
  5. Test harp IHA2D00 if ready for energy spread measurement
  6. Scale cryounit for p=5.487 MeV/c and minimize energy spread
  7. Precisely measure beam momentum
  8. Measure beam emittance
  9. Measure energy spread
  10. Calibrate BCM to FC2