Steps for building Wien filter:
 
Steps for building Wien filter:
  
1. Fabricate coils, magnet (1010 steel), nickel (alloy 200) magnet mirror,  vacuum chamber
+
#Fabricate coils, magnet (1010 steel), nickel (alloy 200) magnet mirror,  vacuum chamber
2. Anneal nickel
+
#Anneal nickel
3. Assemble magnet with end flanges (if possible)
+
#Assemble magnet with end flanges (if possible)
4. Measure magnetic field profile (average a few passes) on centerline
+
#Measure magnetic field profile (average a few passes) on centerline
5. Cut electrode profile to match magnetic profile
+
#Cut electrode profile to match magnetic profile
6. EP electrodes
+
#EP electrodes
7. Assemble with electrodes
+
#Assemble with electrodes

Latest revision as of 13:55, 19 August 2015

Steps for building Wien filter:

  1. Fabricate coils, magnet (1010 steel), nickel (alloy 200) magnet mirror, vacuum chamber
  2. Anneal nickel
  3. Assemble magnet with end flanges (if possible)
  4. Measure magnetic field profile (average a few passes) on centerline
  5. Cut electrode profile to match magnetic profile
  6. EP electrodes
  7. Assemble with electrodes