Difference between revisions of "February 23, 2016 - Elegant Layout"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
This version of UITF is archived at /a/itfdata/uitf/elegant/160223/ | This version of UITF is archived at /a/itfdata/uitf/elegant/160223/ | ||
− | == | + | ===kev.ele=== |
− | + | input file uses beam line G2U which extends from 0.20 m downstream of photocathode to valve upstream of cryounit VBV1M01 | |
− | + | G2U element names are entirely nomenclature per ME song sheet to be released | |
− | + | input conditions are presently guess based on CEBAF 100-130 keV gun with typical laser spot size | |
+ | output file kev.out shows floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891 | ||
+ | |||
+ | ===mev.ele=== | ||
+ | input file uses beam line U2HD which extends from valve upstream cryounit VBV1M01 to final beam dump IDL5M01 | ||
+ | U2HD element names are presently a mix of generic names and nomenclature, until optics and ME design is refined | ||
+ | input conditions are based on CEBAF emittance measurements at 7 MeV/c just after cryounit | ||
+ | note that cryounit is presently treated as a drift, until dimensions for 2-cell and 7-cell are known | ||
+ | output file mev.out shows (continued) floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891 |
Revision as of 17:49, 23 February 2016
This version of UITF is archived at /a/itfdata/uitf/elegant/160223/
kev.ele
input file uses beam line G2U which extends from 0.20 m downstream of photocathode to valve upstream of cryounit VBV1M01 G2U element names are entirely nomenclature per ME song sheet to be released input conditions are presently guess based on CEBAF 100-130 keV gun with typical laser spot size output file kev.out shows floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891
mev.ele
input file uses beam line U2HD which extends from valve upstream cryounit VBV1M01 to final beam dump IDL5M01 U2HD element names are presently a mix of generic names and nomenclature, until optics and ME design is refined input conditions are based on CEBAF emittance measurements at 7 MeV/c just after cryounit note that cryounit is presently treated as a drift, until dimensions for 2-cell and 7-cell are known output file mev.out shows (continued) floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891