* Magnetized beam
 
* Magnetized beam
** Update from Riad.
+
** Magnet fully installed
 +
** Water and electrical connections done
 +
 
  
 
* Some thoughts about the reasons for "QE drops and associated cathode damage spots while running 1 mA DC, 300keV beam"
 
* Some thoughts about the reasons for "QE drops and associated cathode damage spots while running 1 mA DC, 300keV beam"
Line 25: Line 27:
 
** [http://accelconf.web.cern.ch/accelconf/ERL2013/talks/wg103_talk.pdf Bruce Dunham's talk on high current cathode damage]
 
** [http://accelconf.web.cern.ch/accelconf/ERL2013/talks/wg103_talk.pdf Bruce Dunham's talk on high current cathode damage]
 
** [https://wiki.jlab.org/ciswiki/index.php/File:PhysRevSTAB.16.033401.pdf And Russell's paper on the CsK2Sb BNL cathode high current run]
 
** [https://wiki.jlab.org/ciswiki/index.php/File:PhysRevSTAB.16.033401.pdf And Russell's paper on the CsK2Sb BNL cathode high current run]
 +
* Really good suggestions by Joe and Matt:
 +
**'''Bias the anode negative: use it as an ion clearing electrode'''
 +
**'''Existing BPMS CANNOT BE USED ion clearing electrodes because they are 'trip-line' that is they are shorted to ground''
 +
**'''Use the RGA during high current runs to study the gas species during the current/vacuum bursts associated with photocathode arcing events'''

Latest revision as of 06:00, 26 September 2016

  • Cathode Prep Chamber
    • Mamun and Yan successfully demonstrated that the heat-puck engagement mechanism works.
    • A spring with 5 leaves was made by the machine shop. Mamun found out that the height of the bend was too much, so he 'flattened' it bit, making the puck easier to insert and remove.
    • Measured force to disengage puck: about 3 lbs.
    • Also found that the length of the leaves has to be shorter, Mamun had to add a second 'hose clamp'
    • Testing under vacuum, found that several heat-cool cycles kept the puck engaged, but after removal form vacuum springs seemed to be more stiff. Mammon thinks it is because the test temp was as high as 300C, which we do not need. Usual photocathode activation is 150-200 C.
    • Mamun is setting up for a temperature calibration using a TC in vacuum.
  • HV Gun chamber
    • Did a test fit for the NEGs using the rails and the perforated plate, see picture below.
    • NEG perforated plate mockup front view.jpg
    • The gap between the NEG and the perforated plate is about 1 cm.
    • The rails have been tack welded to the chamber
    • Next is assembling the NEG package inside the gun.
  • Magnetized beam
    • Magnet fully installed
    • Water and electrical connections done