Line 1: | Line 1: | ||
− | * Beamline bake | + | * Beamline bake is completed |
− | * New bialkali antimonide photocathode was activated (full area) with QE ~4.8% | + | * New bialkali antimonide photocathode was activated (full area) with QE ~4.8% |
− | * Gain switched diode laser at | + | * Gain switched diode laser at 1066 nm is ready for installation this week (1066 nm, 50 ps Gaussian pulses, doubling efficiency > 30%, 1.5W output, 1497/4=374.25 MHz) |
+ | |||
+ | |||
+ | * Planned measurements: | ||
+ | # Commission harps | ||
+ | # Map beam emittance vs spot location and laser size | ||
+ | # Measure beam magnetization (beam sizes and rotation angle) versus solenoid field from photocathode center and for two laser sizes | ||
+ | # Measure lifetime at 5 mA with RF laser and solenoid magnet off/on |
Latest revision as of 11:24, 4 June 2018
- Beamline bake is completed
- New bialkali antimonide photocathode was activated (full area) with QE ~4.8%
- Gain switched diode laser at 1066 nm is ready for installation this week (1066 nm, 50 ps Gaussian pulses, doubling efficiency > 30%, 1.5W output, 1497/4=374.25 MHz)
- Planned measurements:
- Commission harps
- Map beam emittance vs spot location and laser size
- Measure beam magnetization (beam sizes and rotation angle) versus solenoid field from photocathode center and for two laser sizes
- Measure lifetime at 5 mA with RF laser and solenoid magnet off/on