Difference between revisions of "GTS meeting 7 23 18"

From Ciswikidb
Jump to navigation Jump to search
Line 1: Line 1:
* Summary of lifetime measurements:
+
* Measurements Conditions:
  
 
  Gun = 200 kV, laser rms =0.436 mm, gun solenoid off, Anode bias = +1000 V, Downstream Ion Collector bias = -92 V (one electrode, second electrode is grounded), Upstream Ion Collector bias = -44 V
 
  Gun = 200 kV, laser rms =0.436 mm, gun solenoid off, Anode bias = +1000 V, Downstream Ion Collector bias = -92 V (one electrode, second electrode is grounded), Upstream Ion Collector bias = -44 V
  
 +
* Summary of lifetime measurements:
 
** 10-min Sb Moly substrate photocathode lifetime: [https://logbooks/entry/3581648]
 
** 10-min Sb Moly substrate photocathode lifetime: [https://logbooks/entry/3581648]
 
** 90-min Sb GaAs substrate photocathode lifetime: [https://logbooks/entry/3581623]
 
** 90-min Sb GaAs substrate photocathode lifetime: [https://logbooks/entry/3581623]
 
** 60-min Sb GaAs substrate photocathode lifetime: [https://logbooks/entry/3581644]
 
** 60-min Sb GaAs substrate photocathode lifetime: [https://logbooks/entry/3581644]
 
** 30-min Sb GaAs substrate photocathode lifetime: [https://logbooks/entry/3581642]
 
** 30-min Sb GaAs substrate photocathode lifetime: [https://logbooks/entry/3581642]

Revision as of 08:43, 23 July 2018

  • Measurements Conditions:
Gun = 200 kV, laser rms =0.436 mm, gun solenoid off, Anode bias = +1000 V, Downstream Ion Collector bias = -92 V (one electrode, second electrode is grounded), Upstream Ion Collector bias = -44 V
  • Summary of lifetime measurements:
    • 10-min Sb Moly substrate photocathode lifetime: [1]
    • 90-min Sb GaAs substrate photocathode lifetime: [2]
    • 60-min Sb GaAs substrate photocathode lifetime: [3]
    • 30-min Sb GaAs substrate photocathode lifetime: [4]