* 18" HV chamber NEG coated and originally built with WP NEG modules and wire mesh screen | * 18" HV chamber NEG coated and originally built with WP NEG modules and wire mesh screen | ||
− | * 10" CF flange vacuum fired | + | * 10" CF flange vacuum fired with holes for S&A tooling |
* R30 pure alumina insulator | * R30 pure alumina insulator | ||
* Spherical electrode | * Spherical electrode |
Revision as of 10:32, 20 December 2021
- 18" HV chamber NEG coated and originally built with WP NEG modules and wire mesh screen
- 10" CF flange vacuum fired with holes for S&A tooling
- R30 pure alumina insulator
- Spherical electrode
- Pierce geometry electrode front end
- 2" diameter anode CEBAF style
- Anode-cathode gap 6 cm
- First attempt to HV condition in UITF resulted in punctured ceramic at 160 kV, unusual voltage induced gas desorption. We suspect due to thee NEG coated chamber
- Media:Ball Electrode Drawing marked up by Carlos Dec 16 2021.pdf