Line 18: | Line 18: | ||
: MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved | : MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved | ||
− | == High Voltage | + | == High Voltage Modification == |
− | |||
− | |||
− | |||
− | |||
+ | ==== Standard 100kV Wien HV feedthroughs (20kV/15A) JLAB DCG 32893-0020==== | ||
: ISI/MDC version of P/N | : ISI/MDC version of P/N | ||
:: [https://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&wr=US&p=9272007 ISI=9272001 / MDC=0815002] (20kV/15A) | :: [https://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&wr=US&p=9272007 ISI=9272001 / MDC=0815002] (20kV/15A) | ||
Line 30: | Line 27: | ||
:: [http://www.lesker.com/newweb/feedthroughs/instrument_feedthroughs_shv20_singleend.cfm?pgid=cf Kurt Lesker= IFTXE011152] | :: [http://www.lesker.com/newweb/feedthroughs/instrument_feedthroughs_shv20_singleend.cfm?pgid=cf Kurt Lesker= IFTXE011152] | ||
:: [http://www.lesker.com/newweb/feedthroughs/cablinginstruction_shv20.cfm?pgid=0 20kV feedthrough/cabling (RG-8U)] | :: [http://www.lesker.com/newweb/feedthroughs/cablinginstruction_shv20.cfm?pgid=0 20kV feedthrough/cabling (RG-8U)] | ||
+ | |||
+ | : Modification of Electrode Insulator | ||
+ | :: Increased length by 0.25" see for comparison [[media:171212_longerspacer.pdf]] | ||
+ | |||
+ | : Modification of HV Connector Spring Guide (see JLAB DCG 32893-0137) | ||
+ | :: Increased length by 0.25" see for comparison [[media:171212_longerguide.pdf]] | ||
+ | |||
+ | : [https://logbooks.jlab.org/entry/3430990 Testing of existing feedthrough 20kV] |
Revision as of 12:49, 12 December 2017
Modeling 200kV Wien filter
- J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf
- TOSCA model of air-side magnet assembly, that is (w/o Ni plates in vacuum chamber)
Coil Modified for 20Amp operation
- Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
- Maintain 5.00" ID chamber clearance
Magnet Steel Modifications
- Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
- Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
- COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)
Vacuum Chamber Modifications
- Larger coil width conflicts with magnet mount lugs
- MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved
High Voltage Modification
Standard 100kV Wien HV feedthroughs (20kV/15A) JLAB DCG 32893-0020
- ISI/MDC version of P/N
- Kurt Lesker version of P/N
- Modification of Electrode Insulator
- Increased length by 0.25" see for comparison media:171212_longerspacer.pdf
- Modification of HV Connector Spring Guide (see JLAB DCG 32893-0137)
- Increased length by 0.25" see for comparison media:171212_longerguide.pdf