Difference between revisions of "200kV Wien Filter"
Jump to navigation
Jump to search
Line 34: | Line 34: | ||
== High Voltage Design == | == High Voltage Design == | ||
− | ==== | + | ==== HV feedthroughs (20kV/15A) JLAB DCG 32893-0020==== |
: ISI/MDC version of P/N | : ISI/MDC version of P/N | ||
:: [https://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&wr=US&p=9272007 ISI=9272001 / MDC=0815002] (20kV/15A) | :: [https://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&wr=US&p=9272007 ISI=9272001 / MDC=0815002] (20kV/15A) | ||
Line 42: | Line 42: | ||
:: [http://www.lesker.com/newweb/feedthroughs/cablinginstruction_shv20.cfm?pgid=0 20kV feedthrough/cabling (RG-8U)] | :: [http://www.lesker.com/newweb/feedthroughs/cablinginstruction_shv20.cfm?pgid=0 20kV feedthrough/cabling (RG-8U)] | ||
+ | ==== Vacuum modifications ==== | ||
: Phil/Danny increased the length of the Electrode Insulator (see JLAB DCG 32893-0112) | : Phil/Danny increased the length of the Electrode Insulator (see JLAB DCG 32893-0112) | ||
:: Increased length by 0.25" see for comparison [[media:171212_longerspacer.pdf]] | :: Increased length by 0.25" see for comparison [[media:171212_longerspacer.pdf]] | ||
Line 48: | Line 49: | ||
:: Increased length by 0.25" see for comparison [[media:171212_longerguide.pdf]] | :: Increased length by 0.25" see for comparison [[media:171212_longerguide.pdf]] | ||
+ | ==== Tests ==== | ||
: [https://logbooks.jlab.org/entry/3430990 Brief bench test of 20kV] | : [https://logbooks.jlab.org/entry/3430990 Brief bench test of 20kV] | ||
+ | |||
+ | ==== Power Supplies ==== |
Revision as of 13:29, 12 December 2017
ME Design
Wien filter drawings are up to date (as of June 2017)
- M:\me-group\machie\wien filter
- * main folder has the original fabrication drawings we used.
- * sub folder that has revised version of the original drawings to show the latest as-built changes.
- * sub folder labeled "200KV" that has drawings for the differences in the 200KV wien filter.
- * copy of ECO 1046 that has the analysis of the original vacuum chamber welds.
- * a spreadsheet that lists all the drawings and revision status and applicability.
- Note : we discussed making electrodes from one solid piece of stainless steel instead of five pieces brazed together.
Magnet Design
Jay's TOSCA Modeling
- J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf
- TOSCA model of air-side magnet assembly, that is (w/o Ni plates in vacuum chamber)
Coil Modified for 20Amp operation
- Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
- Maintain 5.00" ID chamber clearance
Magnet Steel Modifications
- Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
- Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
- COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)
Vacuum Chamber Modifications
- Larger coil width conflicts with magnet mount lugs
- MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved
High Voltage Design
HV feedthroughs (20kV/15A) JLAB DCG 32893-0020
- ISI/MDC version of P/N
- Kurt Lesker version of P/N
Vacuum modifications
- Phil/Danny increased the length of the Electrode Insulator (see JLAB DCG 32893-0112)
- Increased length by 0.25" see for comparison media:171212_longerspacer.pdf
- Phil/Danny increased the length of the HV Connector Spring Guide (see JLAB DCG 32893-0137)
- Increased length by 0.25" see for comparison media:171212_longerguide.pdf