Line 5: Line 5:
  
  
* Re-tuned DQWR cavity  
+
* Re-tuned DQWR cavity by rotating power-in coupler (broke vacuum)
  
  

Revision as of 08:25, 11 March 2019

  • Laser frequency is at 499.20025 MHz


  • Shorted out HV power supply conditioning resistor


  • Re-tuned DQWR cavity by rotating power-in coupler (broke vacuum)


  • List of things to do:
  1. RadCon Group to check for x-rays from DQWR cavity
  2. Calibrate new DQWR RF power supply up to 500 W
  3. Measure bunch length using new RF supply
  4. Commission TE011 cavity
  5. Radiation Surveys at 1 mA
  6. Measure Drift Emittance at 100, 200 and 300 kV and laser rms = 0.9 mm
  7. Ghost beam studies with P-Gun - List of experiments here