Difference between revisions of "April 10, 2013"
Jump to navigation
Jump to search
(→=) |
|||
Line 7: | Line 7: | ||
= Topics = | = Topics = | ||
− | Time of flight results | + | Time of flight results |
− | Valeri Toukine's Mott analysis | + | Valeri Toukine's Mott analysis |
− | Removing Mott scattering chamber | + | Removing Mott scattering chamber |
... | ... | ||
− | == | + | == Beam Time == |
− | |||
− | Beam Time | ||
* Beam time for each target using S0 (assume no dependence of Sherman function on target thickness) and no limit on DAQ rate. | * Beam time for each target using S0 (assume no dependence of Sherman function on target thickness) and no limit on DAQ rate. | ||
− | [[Image:euncer_pol.gif| | + | [[Image:euncer_pol.gif|600px]] |
* Beam Time for Gold with target thickness correction and DAQ rate < 5000 Hz. | * Beam Time for Gold with target thickness correction and DAQ rate < 5000 Hz. | ||
− | [[Image:Au_TimeDAQ.gif| | + | [[Image:Au_TimeDAQ.gif|600px]] |
* Beam Time for Silver with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz. | * Beam Time for Silver with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz. | ||
− | [[Image:Ag_TimeDAQ.gif| | + | [[Image:Ag_TimeDAQ.gif|600px]] |
* Beam Time for Copper with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz. | * Beam Time for Copper with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz. | ||
− | [[Image:Cu_TimeDAQ.gif| | + | [[Image:Cu_TimeDAQ.gif|600px]] |
* Note: Target thickness extrapolation used above: | * Note: Target thickness extrapolation used above: |
Revision as of 08:11, 10 April 2013
We will meet in ARC 428 on Wednesday April 10 at 3pm EST.
For those calling in we'll use the ReadyTalk audio conference system.
1. Dial Toll-Free Number: 866-740-1260 (U.S. & Canada) 2. Enter 7-digit access code 3441852, followed by “#”
Topics
Time of flight results Valeri Toukine's Mott analysis Removing Mott scattering chamber
...
Beam Time
* Beam time for each target using S0 (assume no dependence of Sherman function on target thickness) and no limit on DAQ rate.
* Beam Time for Gold with target thickness correction and DAQ rate < 5000 Hz.
* Beam Time for Silver with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz.
* Beam Time for Copper with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz.
* Note: Target thickness extrapolation used above:
- Alpha as a function of Kinetic Energy: alpha = 0.0066 + 0.052 * kine
- Effective Sherman Function: eff_sf = S0 /(1.0 + alpha * d)