Difference between revisions of "CIS-ASY-R30-3"

From Ciswikidb
Jump to navigation Jump to search
(Created page with "* 18" HV chamber NEG coated and originally built with WP NEG modules and wire mesh screen * 10" CF flange vacuum fired * R30 pure alumina insulator * Spherical electrode * Pie...")
 
Line 7: Line 7:
 
* Anode-cathode gap 6 cm
 
* Anode-cathode gap 6 cm
 
* First attempt to HV condition in UITF resulted in punctured ceramic at 160 kV, unusual voltage induced gas desorption. We suspect due to thee NEG coated chamber
 
* First attempt to HV condition in UITF resulted in punctured ceramic at 160 kV, unusual voltage induced gas desorption. We suspect due to thee NEG coated chamber
 +
* [[Media:Ball Electrode Drawing marked up by Carlos Dec 16 2021.pdf]]
 +
*[https://wiki.jlab.org/ciswiki/index.php/Gun_assemblies,_electrostatic_models_and_field_maps Back to gun assemblies]

Revision as of 10:30, 20 December 2021

  • 18" HV chamber NEG coated and originally built with WP NEG modules and wire mesh screen
  • 10" CF flange vacuum fired
  • R30 pure alumina insulator
  • Spherical electrode
  • Pierce geometry electrode front end
  • 2" diameter anode CEBAF style
  • Anode-cathode gap 6 cm
  • First attempt to HV condition in UITF resulted in punctured ceramic at 160 kV, unusual voltage induced gas desorption. We suspect due to thee NEG coated chamber
  • Media:Ball Electrode Drawing marked up by Carlos Dec 16 2021.pdf