Difference between revisions of "Mar 27 2024"

From Ciswikidb
Jump to navigation Jump to search
Line 9: Line 9:
 
** S&A surveyed the gun chamber to find the chamber z axis.
 
** S&A surveyed the gun chamber to find the chamber z axis.
 
** Then S&A established a laser launch coincidental with the gun chamber z-axis
 
** Then S&A established a laser launch coincidental with the gun chamber z-axis
** As preliminary testing, we inserted a mirror puck. The retro-reflection indicates the plane of the mirror puck is ~ 0.8 degree w.r.t. the chamber axis.  
+
** As <u>'''''preliminary testing'''''</u>, we inserted a mirror puck. The retro-reflection indicates the plane of the mirror puck is ~ 0.8 degree w.r.t. the chamber axis.  
 
** We will do more retro-reflection testing with a molybdenum puck and GaAs wafer once the Teflon puck manipulator arrives from the shop.
 
** We will do more retro-reflection testing with a molybdenum puck and GaAs wafer once the Teflon puck manipulator arrives from the shop.
  
Line 16: Line 16:
  
 
[[File:R30-3 gun in LERF Lab 3A cleanroom 01.jpg|left|middle|thumb]]
 
[[File:R30-3 gun in LERF Lab 3A cleanroom 01.jpg|left|middle|thumb]]
 
  
 
=<br  />=
 
=<br  />=

Revision as of 16:06, 26 March 2024

Updates

  • Fabrication
    • A new puck manipulator made out of Teflon and 24 inches long was designed and drawing submitted to the shop for fabrication. This manipulator will be used to insert pucks into the spherical electrode while still mounted to the gun vacuum chamber during S&A and laser retro-reflection chess in the LERF Lab 3A clean room.
    • File:JL0163328, PUCK MANIPULATOR END ADAPTER TEFLON 24 in long.pdf
  • S&A checks of the R30-3 gun in LERF Lab 3A clean room. See details [[1]]
    • The R30-3 gun vacuum chamber was mounted on a sturdy 80/20 frame table with optical breadboard top.
    • S&A surveyed the gun chamber to find the chamber z axis.
    • Then S&A established a laser launch coincidental with the gun chamber z-axis
    • As preliminary testing, we inserted a mirror puck. The retro-reflection indicates the plane of the mirror puck is ~ 0.8 degree w.r.t. the chamber axis.
    • We will do more retro-reflection testing with a molybdenum puck and GaAs wafer once the Teflon puck manipulator arrives from the shop.



R30-3 gun in LERF Lab 3A cleanroom 01.jpg


Return to 200 kV Gun page






S&A established laser launch along chamber z-axis 02.jpg















Back end with laser beam through HVC.jpg











Preliminary retro-reflection with mirror puck electrode still mounted to HVC.jpg