200kV Wien Filter
Revision as of 09:39, 4 May 2017 by Grames (talk | contribs) (Created page with "J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf == Coil Modified for 20Amp operation == : Replace 2 layer X 14 turn/layer #16 round wire w/ 2 la...")
J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf
Coil Modified for 20Amp operation
- Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
- Maintain 5.00" ID chamber clearance
Magnet Steel Modifications
- Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
- Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
- COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)
Vacuum Chamber Modifications
- Larger coil width conflicts with magnet mount lugs
- MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved