200kV Wien Filter

From Ciswikidb
Revision as of 11:56, 12 December 2017 by Grames (talk | contribs)
Jump to navigation Jump to search

Modeling 200kV Wien filter

J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf
TOSCA model of air-side magnet assembly, that is (w/o Ni plates in vacuum chamber)
media:wien_noNi_B_10A.table.txt
media:wien_noNi_B_15A.table.txt

Coil Modified for 20Amp operation

Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
Maintain 5.00" ID chamber clearance

Magnet Steel Modifications

Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)

Vacuum Chamber Modifications

Larger coil width conflicts with magnet mount lugs
MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved

High Voltage Modification

Standard 100kV Wien HV feedthroughs (20kV/15A) JLAB DCG 32893-0020

ISI/MDC version of P/N
ISI=9272001 / MDC=0815002 (20kV/15A)
MDC install kit (old ISI # 0263202 not found)
Kurt Lesker version of P/N
Kurt Lesker= IFTXE011152
20kV feedthrough/cabling (RG-8U)
Modification of Electrode Insulator
Increased length by 0.25" see for comparison media:171212_longerspacer.pdf
Modification of HV Connector Spring Guide (see JLAB DCG 32893-0137)
Increased length by 0.25" see for comparison media:171212_longerguide.pdf
Brief bench test of 20kV