Meeting Info

We will meet Friday @ 1pm EDT via BlueJeans
Meeting ID: 344693443# 
Moderator Passcode: 3141
Meeting URL (for video and/or audio call in): https://bluejeans.com/344693443
Phone number (for audio call in): 1-888-240-2560

Agenda

  • Radmon calibration
  • I thought this study was done in a way to dump the beam very close to the steering coils, but in fact it does not appear to be this way in all cases.
  • The cases for exciting MBH2I02V (middle) and MBH2I03V (end) of NEG tube suggest the radmon detector senstivity there to 130 keV electrons is about 0.1-1 count/nA of loss.
  • The radmon5 detector is located at the VWien entrance, first small aperture (10mm diameter), and the response there is the largest to the beam striking normally with sensitivities of 0.3-20 count/nA.

Back Links

Return to Ionization Effects Meetings

Go to Minutes for this meeting