Max: Some misleading links to a previous meeting have accidentally been hardcoded on this page. Can't click the edit buttons next to the section headings.
Updates from last meeting action items[edit|edit source]
- Gabriel:
- Alicia
- Max:
- Tolerance on hole diameter
- Comparison 6.2 mm and 6.4 mm
- Seems to be a 10% effect
- Junction angle, does it matter optically?
- Comparison 30 and 60 degrees
- Also seems to be a 10% effect
- Effect of edge radius at junction
- Zoomed out
- 0.5 mm radius
- 0.25 mm radius
- 0.25 mm radius, protruding lip
- This may not end up being a big deal. The protruding case has the worst field enhancement, perhaps 20%, need finer mesh to quantify. Small radius w/o protrusion is best, barely worse than a smooth joint.
- CST vs Poisson
- Comparing Ez for a test case
- Not exactly equal, not 100% sure yet if caused by different geometry or cylindrical symmetry
- Tolerance on hole diameter
- Carlos: Created table of parameters and SharePoint site
Items for discussion[edit|edit source]
Action items for next meeting[edit|edit source]