Line 20: Line 20:
 
== Electrode modified for 20kV operation ==
 
== Electrode modified for 20kV operation ==
 
* [https://logbooks.jlab.org/entry/3430990 Testing of existing feedthrough 20kV]
 
* [https://logbooks.jlab.org/entry/3430990 Testing of existing feedthrough 20kV]
 +
 +
=== Wien Filter Assembly Electrical Feedthrough (JLAB DCG 32893-0020)
 +
* [https://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&wr=US&p=9272007 ISI=9272001 / MDC=0815002] (20kV/15A)
 +
* [http://www.lesker.com/newweb/feedthroughs/instrument_feedthroughs_shv20_singleend.cfm?pgid=cf Kurt Lesker= IFTXE011152]

Revision as of 12:23, 12 December 2017

Modeling 200kV Wien filter

J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf
TOSCA model of air-side magnet assembly, that is (w/o Ni plates in vacuum chamber)
media:wien_noNi_B_10A.table.txt
media:wien_noNi_B_15A.table.txt

Coil Modified for 20Amp operation

Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
Maintain 5.00" ID chamber clearance

Magnet Steel Modifications

Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)

Vacuum Chamber Modifications

Larger coil width conflicts with magnet mount lugs
MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved

Electrode modified for 20kV operation

=== Wien Filter Assembly Electrical Feedthrough (JLAB DCG 32893-0020)