Difference between revisions of "200kV Wien Filter"

From Ciswikidb
Jump to navigation Jump to search
Line 21: Line 21:
 
* [https://logbooks.jlab.org/entry/3430990 Testing of existing feedthrough 20kV]
 
* [https://logbooks.jlab.org/entry/3430990 Testing of existing feedthrough 20kV]
  
=== Wien Filter Assembly Electrical Feedthrough (JLAB DCG 32893-0020)
+
=== Wien Filter Assembly Electrical Feedthrough (JLAB DCG 32893-0020) ===
 
==== ISI/MDC ====
 
==== ISI/MDC ====
* [https://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&wr=US&p=9272007 ISI=9272001 / MDC=0815002] (20kV/15A)
+
: [https://www.mdcvacuum.com/DisplayPart.aspx?d=MDC&wr=US&p=9272007 ISI=9272001 / MDC=0815002] (20kV/15A)
* [https://www.mdcvacuum.com/DisplayPart.aspx?p=9912452 MDC install kit (old ISI # 0263202 not found)]
+
: [https://www.mdcvacuum.com/DisplayPart.aspx?p=9912452 MDC install kit (old ISI # 0263202 not found)]
 
====Kurt Lesker====
 
====Kurt Lesker====
* [http://www.lesker.com/newweb/feedthroughs/instrument_feedthroughs_shv20_singleend.cfm?pgid=cf Kurt Lesker= IFTXE011152]
+
: [http://www.lesker.com/newweb/feedthroughs/instrument_feedthroughs_shv20_singleend.cfm?pgid=cf Kurt Lesker= IFTXE011152]
* [http://www.lesker.com/newweb/feedthroughs/cablinginstruction_shv20.cfm?pgid=0 20kV feedthrough/cabling (RG-8U)]
+
: [http://www.lesker.com/newweb/feedthroughs/cablinginstruction_shv20.cfm?pgid=0 20kV feedthrough/cabling (RG-8U)]

Revision as of 12:34, 12 December 2017

Modeling 200kV Wien filter

J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf
TOSCA model of air-side magnet assembly, that is (w/o Ni plates in vacuum chamber)
media:wien_noNi_B_10A.table.txt
media:wien_noNi_B_15A.table.txt

Coil Modified for 20Amp operation

Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
Maintain 5.00" ID chamber clearance

Magnet Steel Modifications

Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)

Vacuum Chamber Modifications

Larger coil width conflicts with magnet mount lugs
MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved

Electrode modified for 20kV operation

Wien Filter Assembly Electrical Feedthrough (JLAB DCG 32893-0020)

ISI/MDC

ISI=9272001 / MDC=0815002 (20kV/15A)
MDC install kit (old ISI # 0263202 not found)

Kurt Lesker

Kurt Lesker= IFTXE011152
20kV feedthrough/cabling (RG-8U)