Difference between revisions of "200kV Wien Filter"

From Ciswikidb
Jump to navigation Jump to search
(8 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
These pages contain materials for modifying the standard CEBAF Wien filter design (originally SLAC 100kV Wien filter) for operation at 200kV.
 
These pages contain materials for modifying the standard CEBAF Wien filter design (originally SLAC 100kV Wien filter) for operation at 200kV.
  
[[Wien Filter References]]
+
===200 kV Wien HV Controls===
 +
::[[200kV High Voltage Power Supply & Controls]]
  
[[200kV Wien filter - V1]] - First iteration to modify CEBAF Wien filter for 200kV operation, fabricated per Jay's proposal, and installed at UITF 2017
+
===200 kV Wien Magnet===
 +
::Feb 11, 2020 - Final coil design [[media:200KeVWienFIlter-32893-D-0131.pdf]]
 +
::Mar 10, 2020 - Vendor has begun coil winding [[media:20200305_145427.jpg]]
  
[[200kV Wien filter - V2]] -
+
===200 kV Wien Assembly===
 +
::[[Media:UITF Wien filter traveler May 11 2020.docx]]
  
[[200kV High Voltage Power Supply Controls]]
+
===CEBAF Wien Filter Upgrade Iterations===
 +
 
 +
::[[200kV Wien filter - V3]] - Third iteration modeled in CST by Gabriel with improved 40 kV feedthroughs has demonstrated (2019) 20kV per plate at UITF on a test stand but test still undergoing. Intended as a testbed for 20kV switch chassis test in preparation for implementation at CEBAF.
 +
 
 +
::[[200kV Wien filter - V2]] - Second iteration built using 20kV feedthroughs and HV tested in UITF beamline 2018 to ~12 kV limited by large vacuum excursions
 +
 
 +
::[[200kV Wien filter - V1]] - First iteration to modify CEBAF Wien filter for 200kV operation, fabricated per Jay's proposal, and installed at UITF 2017
 +
 
 +
===[[Wien Filter References]]===

Revision as of 13:02, 11 May 2020

These pages contain materials for modifying the standard CEBAF Wien filter design (originally SLAC 100kV Wien filter) for operation at 200kV.

200 kV Wien HV Controls

200kV High Voltage Power Supply & Controls

200 kV Wien Magnet

Feb 11, 2020 - Final coil design media:200KeVWienFIlter-32893-D-0131.pdf
Mar 10, 2020 - Vendor has begun coil winding media:20200305_145427.jpg

200 kV Wien Assembly

Media:UITF Wien filter traveler May 11 2020.docx

CEBAF Wien Filter Upgrade Iterations

200kV Wien filter - V3 - Third iteration modeled in CST by Gabriel with improved 40 kV feedthroughs has demonstrated (2019) 20kV per plate at UITF on a test stand but test still undergoing. Intended as a testbed for 20kV switch chassis test in preparation for implementation at CEBAF.
200kV Wien filter - V2 - Second iteration built using 20kV feedthroughs and HV tested in UITF beamline 2018 to ~12 kV limited by large vacuum excursions
200kV Wien filter - V1 - First iteration to modify CEBAF Wien filter for 200kV operation, fabricated per Jay's proposal, and installed at UITF 2017

Wien Filter References