Difference between revisions of "200kV Wien Filter"

From Ciswikidb
Jump to navigation Jump to search
(Created page with "J. Benesch, "Modeling the SLAC/JLab Wien filter" media:JLab-TN-15-032.pdf == Coil Modified for 20Amp operation == : Replace 2 layer X 14 turn/layer #16 round wire w/ 2 la...")
 
(Blanked the page)
 
(35 intermediate revisions by 2 users not shown)
Line 1: Line 1:
J. Benesch, "Modeling the SLAC/JLab Wien filter" [[media:JLab-TN-15-032.pdf]]
 
  
== Coil Modified for 20Amp operation ==
 
: Replace 2 layer X 14 turn/layer #16 round wire w/ 2 layer X 13 turn/layer #13 square wire
 
: Maintain 5.00" ID chamber clearance
 
 
== Magnet Steel Modifications ==
 
: Coil fits within existing transverse gap (chamber to steel), but not within existing vertical gap (conflicts electrode ports)
 
: Channels are cut into upper and lower steel yokes to allow coils to separate further (remove conflicts w/ electrode ports)
 
: COIL RETAINER PLATES (32893-C-0008) flipped hold coil 0.124" further from mid plane (0.312 - 0.188 inches)
 
 
== Vacuum Chamber Modifications ==
 
: Larger coil width conflicts with magnet mount lugs
 
: MAGNET MOUNT LUG (32893-C-0024) width reduced from 1.45 to 0.95 inches welded to vacuum chamber body reduced and moved
 
 
== Electrode modified for 20kV operation ==
 

Latest revision as of 14:06, 27 August 2020