:[[Media:Wien filter modeled in CTS by Gabriel and tested to 20kV per plate in UITF 2019.pptx]]
+
*The version of the Wien filter described here is an improved version of the one tested in UITF beamline with the following changes:
 +
** 40 kV CeramTec HV feedthroughs (3/4" diameter).
 +
** Spring-guide to couple to 40 kV feedthrough
 +
** Spring to match design, but we had to use some that are slightly magnetic. Danny ordered new non-magnetic springs and gave them to Phil.
 +
** HV tests have been performed without the magnet coil and without the iron yokes
 +
**:[[Media:Wien filter modeled in CTS by Gabriel and tested to 20kV per plate in UITF 2019.pptx]]
 +
**:[https://logbooks.jlab.org/entry/3733762 Gabriel's first test with 40 kV feedthroughs applying 19 kV per plate Wien on test stand]
 +
**[[Media:Update from Carlos for AIPINJ meeting March 20 2020.pptx]]
 +
**[[Media:Wien filter shorter plate gaps.pptx]]
 +
**[[Media:Wien_filter_bolts_and_washers.pptx]]
 +
**[[Media:CST licence expires April 15 2020 this is the renewal quote.PDF]]
 +
**[[File:Vacuum vs applied voltage Wien rebuilt with alumina screws and washers.pdf]]
 +
**[[Media:Electrode shape E field compare with measured Bx.pptx]]
 +
 
 +
; Oct 24 2019 - Wien magnet assembly at UITF
 +
* [[media:191024_UITF_Wien.pptx]]