Difference between revisions of "2018 Mott Paper Working Area"

From Ciswikidb
Jump to navigation Jump to search
Line 20: Line 20:
 
==Paper Plots==
 
==Paper Plots==
 
*'''Plots Still Needed'''
 
*'''Plots Still Needed'''
 +
: Request #2.  We measured dependence of the physics asymmetry on the position of the beam on the target foil from two target foils:  0.225um and 1um.  For each foil we measured 7 asymmetries (one at center and six others away from center).  The details are described in the systematics TN on the wiki.  He'd like a plot showing the measured physics asymmetries (weighted average of IN/OUT) vs. radial distance from the center (instead of using x/y values shown in the TN), and then the average with it's uncertainty band, for the two target foils.
 
::*Asymmetry vs Beam Position from Nominal (radially)
 
::*Asymmetry vs Beam Position from Nominal (radially)
::*recreate Michael's Paper's Plot
+
 
 +
: Request #3 - Recreate Michael's Paper's Plot
 
::** Remaking of Figure 6: [[media:Au_targetMSteigerwald.gif]]. The lines are a fit ( asym = a / (1.0 + alpha . d) ). On the original figure, the lines were his calculations.
 
::** Remaking of Figure 6: [[media:Au_targetMSteigerwald.gif]]. The lines are a fit ( asym = a / (1.0 + alpha . d) ). On the original figure, the lines were his calculations.
  
  
 
*'''Asymmetry vs Deadtime/Beam Current'''
 
*'''Asymmetry vs Deadtime/Beam Current'''
 +
: Request #1. We measured dependence of electronic dead time on the beam current at five different average beam currents from 0.245-4.1 uA on a 1um foil.  He'd like a plot showing the five data points vs. beam current with their individual uncertainties, and then the average with it's uncertainty band.
 +
 
::[[media:Deadtime vs beamcurrent.ods]]
 
::[[media:Deadtime vs beamcurrent.ods]]
 
::[[File:Asym v beamcurrent.gif||600px]]
 
::[[File:Asym v beamcurrent.gif||600px]]
 
::[[File:Avg asym v beamcurrent.gif||600px]]
 
::[[File:Avg asym v beamcurrent.gif||600px]]
 
::[[File:Avg deadtime v beamcurrent.gif||600px]]
 
::[[File:Avg deadtime v beamcurrent.gif||600px]]

Revision as of 09:54, 2 November 2018

General Links/Documents

  • Run 1
Online Analysis Spreadsheet : media:run1database.ods
Asymmetry vs Foil Thickness Full Analysis Spreadsheet : media:06.01.17_Run1_ARC+Dilution.ods
  • Run 2
Online Analysis Spreadsheet : Media:Run2RawData.ods
Asymmetry vs Foil Thickness Full Analysis Spreadsheet : media:06.01.17_Run2_ARC+Dilution.ods

Paper Section Drafts

Paper Plots

  • Plots Still Needed
Request #2. We measured dependence of the physics asymmetry on the position of the beam on the target foil from two target foils: 0.225um and 1um. For each foil we measured 7 asymmetries (one at center and six others away from center). The details are described in the systematics TN on the wiki. He'd like a plot showing the measured physics asymmetries (weighted average of IN/OUT) vs. radial distance from the center (instead of using x/y values shown in the TN), and then the average with it's uncertainty band, for the two target foils.
  • Asymmetry vs Beam Position from Nominal (radially)
Request #3 - Recreate Michael's Paper's Plot
    • Remaking of Figure 6: media:Au_targetMSteigerwald.gif. The lines are a fit ( asym = a / (1.0 + alpha . d) ). On the original figure, the lines were his calculations.


  • Asymmetry vs Deadtime/Beam Current
Request #1. We measured dependence of electronic dead time on the beam current at five different average beam currents from 0.245-4.1 uA on a 1um foil. He'd like a plot showing the five data points vs. beam current with their individual uncertainties, and then the average with it's uncertainty band.
media:Deadtime vs beamcurrent.ods
Asym v beamcurrent.gif
Avg asym v beamcurrent.gif
Avg deadtime v beamcurrent.gif