Apr 17 2024

From Ciswikidb
Revision as of 09:51, 15 April 2024 by Chgarcia (talk | contribs) (Created page with "==Updates== * The electrode front end pieces 16-30 deg and 16-60 deg, two pieces each manufactured from 316 VAR SS have been polished in the SRF tumbler, UHV cleaned in the C...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Updates

  • The electrode front end pieces 16-30 deg and 16-60 deg, two pieces each manufactured from 316 VAR SS have been polished in the SRF tumbler, UHV cleaned in the Chem room, and vacuum degassed din the vacuum furnace room. They are ready for assembly.
  • The electrode was removed from the high voltage chamber, and disassembled for checking the tension on the sapphire roller springs, suspected to be too weak thus leading to irreproducibility in the laser retreat-reflection:

Schedule Discussion


Return to 200 kV Gun page