Difference between revisions of "April 10, 2013"

From Ciswikidb
Jump to navigation Jump to search
(Created page with "We will meet in ARC 428 on Wednesday April 10 at 3pm EST. == For those calling in we'll use the ReadyTalk audio conference system. == 1. Dial Toll-Free Number: 866-740-1260 (U....")
 
 
(32 intermediate revisions by 2 users not shown)
Line 7: Line 7:
 
= Topics =
 
= Topics =
  
Time of flight results
+
== Removing Mott scattering chamber ==
Valeri Toukine's Mott analysis
+
[[Media:130410_Dismount.pdf]]
Removing Mott scattering chamber
+
 
...
+
== Time of flight results ==
 +
[[Media:130410_TOF.pdf]]
 +
 
 +
== Valeri Tioukine's Mott analysis ==
 +
[[Media:Tioukine_MITPEB.pdf]]
 +
 
 +
== Beam Time ==
 +
* Beam time for each target using S0 (assume no dependence of Sherman function on target thickness) and no limit on DAQ rate.
 +
Gold (Au, Z=79), Silver (Ag, Z=47), Copper (Cu, Z=29). Note that:
 +
Figure of Merit (fom) ~ sigma * S^2 ~ Z^4.
 +
Beam Time ~ 1/fom = 1/Z^4
 +
 
 +
[[Image:euncer_pol.gif|600px]]
 +
 
 +
* Beam Time for Gold with target thickness correction and DAQ rate < 5000 Hz.
 +
 
 +
[[Image:Au_TimeDAQ.gif|600px]]
 +
 
 +
* Beam Time for Silver with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz.
 +
 
 +
[[Image:Ag_TimeDAQ.gif|600px]]
 +
 
 +
* Beam Time for Copper with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz.
 +
 
 +
[[Image:Cu_TimeDAQ.gif|600px]]
 +
 
 +
* Note: Target thickness extrapolation used above:
 +
- Alpha as a function of Kinetic Energy: alpha = 0.0066 + 0.052 * kine
 +
 
 +
- Effective Sherman Function: eff_sf = S0 /(1.0 +  alpha * d)
 +
 
 +
[[Image:Au_target1.gif|500px]]
 +
 
 +
[[Image:Au_alpha1.gif|500px]]

Latest revision as of 14:50, 10 April 2013

We will meet in ARC 428 on Wednesday April 10 at 3pm EST.

For those calling in we'll use the ReadyTalk audio conference system.

1. Dial Toll-Free Number: 866-740-1260 (U.S. & Canada)
2. Enter 7-digit access code 3441852, followed by “#”

Topics

Removing Mott scattering chamber

Media:130410_Dismount.pdf

Time of flight results

Media:130410_TOF.pdf

Valeri Tioukine's Mott analysis

Media:Tioukine_MITPEB.pdf

Beam Time

* Beam time for each target using S0 (assume no dependence of Sherman function on target thickness) and no limit on DAQ rate. 
Gold (Au, Z=79), Silver (Ag, Z=47), Copper (Cu, Z=29). Note that:
Figure of Merit (fom) ~ sigma * S^2 ~ Z^4. 
Beam Time ~ 1/fom = 1/Z^4

Euncer pol.gif

* Beam Time for Gold with target thickness correction and DAQ rate < 5000 Hz.

Au TimeDAQ.gif

* Beam Time for Silver with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz.

Ag TimeDAQ.gif

* Beam Time for Copper with target thickness correction using Gold extrapolation and DAQ rate < 5000 Hz.

Cu TimeDAQ.gif

* Note: Target thickness extrapolation used above:

- Alpha as a function of Kinetic Energy: alpha = 0.0066 + 0.052 * kine

- Effective Sherman Function: eff_sf = S0 /(1.0 + alpha * d)

Au target1.gif

Au alpha1.gif