Difference between revisions of "Beam Setup and Measurement - May 2018"
Jump to navigation
Jump to search
Line 36: | Line 36: | ||
::: Type command '''''sddsprintout -col=ElementName -col=betax -col=etax energyspread.twi''''' | ::: Type command '''''sddsprintout -col=ElementName -col=betax -col=etax energyspread.twi''''' | ||
::: Record value of betax[m] and etax[m] at IHA2D00 | ::: Record value of betax[m] and etax[m] at IHA2D00 | ||
+ | |||
+ | == Set Beam at Radiator == | ||
+ | |||
+ | :Pre-requisites for the measurement | ||
+ | ::Measured beam momentum in units of MeV/c | ||
+ | ::Measured normalized emittance and Twiss parameters at MQJ0L02 (e.g. from qsUtility) | ||
+ | ::Measured relative momentum spread (dp/p) (e.g. 1% is 0.01) | ||
+ | :Use Elegant to calculate quad values (MQJ0L02, MQJ0L02A, MQD5D00, MQD5D01) to set beam size at radiator IDL5D01 and compare at harp IHA5D01 |
Revision as of 11:15, 9 May 2018
Energy Setup and Measurement
- ...
Emittance Measurement
- Setup beam to FC2
- Use qsUtility configuration files to scan MQJ0L02 and/or MQJ0L02A and uses harp IHA0L03
- Be sure to enter the correct momentum in the configuration and/or analysis files
- Elegant optics lattice begins at MQJ0L02 (that is, use or propagate optics to that location)
Elegant Optics Model
- September 2015 - Chris Tennant's Model copied here for reference /usr/opsdata/bubble/elegant/Sep2015
- May 2018 - Updated to include 2D spectrometer line and new harp IHA5D01 /usr/opsdata/bubble/elegant/May2018
Energy Spread Measurement
- Setup beam to 2D spectrometer dump
- Upstream quads MQJ0L02 and MQJ0L02A can be any value but their integrated gradient value B'L (.BL field) must be recorded
- Use HarpFitterTool to scan IHA2D00 to measure horizontal beam size
- Use Elegant to calculate the horizontal beta (betax) and the horizontal dispersion (etax) at the harp location
- Update lattice file
- Type command cd /usr/opsdata/bubble/elegant/May2018/lattice
- Edit lattice file BubbleChamber.lte
- Update K1 values for MQJ0L02/MQJ0L02A (they appear in only one place)
- Update energy spread elegant file
- Type command cd /usr/opsdata/bubble/elegant/May2018/energy_spread
- Edit command file energyspread.ele
- Update p_central_mev[MeV/c]
- Update beta_x[m] and beta_y[m] with qsUtility values computed at MQJ0L02
- Update emit_nx[m-rad] and emit_ny[m-rad] with qsUtility values compated at MQJ0L02
- Run Elegant model
- Type command cd /usr/opsdata/bubble/elegant/May2018/energy_spread
- Type command elegant energyspread.ele
- Type command sddsprintout -col=ElementName -col=betax -col=etax energyspread.twi
- Record value of betax[m] and etax[m] at IHA2D00
- Update lattice file
Set Beam at Radiator
- Pre-requisites for the measurement
- Measured beam momentum in units of MeV/c
- Measured normalized emittance and Twiss parameters at MQJ0L02 (e.g. from qsUtility)
- Measured relative momentum spread (dp/p) (e.g. 1% is 0.01)
- Use Elegant to calculate quad values (MQJ0L02, MQJ0L02A, MQD5D00, MQD5D01) to set beam size at radiator IDL5D01 and compare at harp IHA5D01