Difference between revisions of "CIS-ASY-R30-1"

From Ciswikidb
Jump to navigation Jump to search
 
(4 intermediate revisions by the same user not shown)
Line 10: Line 10:
 
*Gun assembly removed form beam line in 2018 to make room for Thermionic gun program.
 
*Gun assembly removed form beam line in 2018 to make room for Thermionic gun program.
  
*[[Media:Ball Electrode Drawing marked up by Carlos Dec 16 2021.pdf]]
+
*[[Media:ACC-200-3000-0460 SPHERICAL ELECTRODE SHELL_S&A annotated.pdf]]
 
*[[Media:Ball back face.pdf]]
 
*[[Media:Ball back face.pdf]]
*[[Media:Ball Electrode front end.pdf]]
+
*[[Media:Ball front face.pdf]]
 
*[[Media:GTS gun chamber 2D drawing by Gary Hays.pdf]]
 
*[[Media:GTS gun chamber 2D drawing by Gary Hays.pdf]]
*[[Media:Modified puck holder for welded ball.pdf]]
+
*[[Media:Puck holder modified.pdf]]
 
*[[Media:Vacuum Chamber Drawing.pdf]]
 
*[[Media:Vacuum Chamber Drawing.pdf]]
 +
*[[Media:Vacuum Chamber Dimensions.pdf]]
  
 
*[[File:350kV Gun with Guts blue puck.jpg]]
 
*[[File:350kV Gun with Guts blue puck.jpg]]

Latest revision as of 10:56, 20 December 2021

  • 18" HV chamber with WP NEG modules and perforated shield screen
  • 10" CF flange vacuum fired and engraved with CIS-ASY-R30-1 reference
  • R30 doped alumina insulator
  • Spherical electrode
  • Pierce geometry electrode front end
  • 6" anode diameter with raised up hole and with holes for laser in/out at 25 deg incidence
  • 9 cm anode-cathode gap
  • Delivered 300 keV beam in GTS
  • Gun assembly removed form beam line in 2018 to make room for Thermionic gun program.
  • 350kV Gun with Guts blue puck.jpg
  • BlackR30 & SS electrodesISO.jpg
  • Anode plate John's design.jpg