Line 7: Line 7:
 
*6" anode diameter with raised up hole and with holes for laser in/out at 25 deg incidence
 
*6" anode diameter with raised up hole and with holes for laser in/out at 25 deg incidence
 
*9 cm anode-cathode gap
 
*9 cm anode-cathode gap
*
+
*[https://journals.aps.org/prab/pdf/10.1103/PhysRevAccelBeams.22.113401 Delivered 300 keV beam in GTS]
 +
*Gun assembly removed form beam line in 2018 to make room for Thermionic gun program.
 +
 
 +
*[[Media:ACC-200-3000-0460 SPHERICAL ELECTRODE SHELL_S&A annotated.pdf]]
 +
*[[Media:Ball back face.pdf]]
 +
*[[Media:Ball front face.pdf]]
 +
*[[Media:GTS gun chamber 2D drawing by Gary Hays.pdf]]
 +
*[[Media:Puck holder modified.pdf]]
 +
*[[Media:Vacuum Chamber Drawing.pdf]]
 +
*[[Media:Vacuum Chamber Dimensions.pdf]]
 +
 
 +
*[[File:350kV Gun with Guts blue puck.jpg]]
 +
*[[File:BlackR30 & SS electrodesISO.jpg]]
 +
*[[File:Anode plate John's design.jpg]]
 +
 
 +
 
 +
*[https://wiki.jlab.org/ciswiki/index.php/Gun_assemblies,_electrostatic_models_and_field_maps Back to gun assemblies]

Latest revision as of 10:56, 20 December 2021

  • 18" HV chamber with WP NEG modules and perforated shield screen
  • 10" CF flange vacuum fired and engraved with CIS-ASY-R30-1 reference
  • R30 doped alumina insulator
  • Spherical electrode
  • Pierce geometry electrode front end
  • 6" anode diameter with raised up hole and with holes for laser in/out at 25 deg incidence
  • 9 cm anode-cathode gap
  • Delivered 300 keV beam in GTS
  • Gun assembly removed form beam line in 2018 to make room for Thermionic gun program.
  • 350kV Gun with Guts blue puck.jpg
  • BlackR30 & SS electrodesISO.jpg
  • Anode plate John's design.jpg