* [https://wiki.jlab.org/ciswiki/index.php/18%22_Photogun_ala_GTS this assembly is being developed as th next CEBAF 200 kV gun based on the GTS design]
 
* 18" HV chamber NEG coated and originally built with WP NEG modules and wire mesh screen
 
* 18" HV chamber NEG coated and originally built with WP NEG modules and wire mesh screen
 
* 10" CF flange vacuum fired with holes for S&A tooling
 
* 10" CF flange vacuum fired with holes for S&A tooling
Line 5: Line 6:
 
* Pierce geometry electrode front end
 
* Pierce geometry electrode front end
 
* 2" diameter anode CEBAF style
 
* 2" diameter anode CEBAF style
* Anode-cathode gap 6 cm
+
* Anode-cathode gap 2.506 inches from flat face of anode to the face of the GaAs wafer
 
* First attempt to HV condition in UITF resulted in punctured ceramic at 160 kV, unusual voltage induced gas desorption. We suspect due to thee NEG coated chamber
 