CODA Summary

From Ciswikidb
Revision as of 10:12, 30 October 2013 by Suleiman (talk | contribs)
Jump to navigation Jump to search

Summary of CODA Configurations

Name Readout Output Trigger
Scalers Scaler S1 (helicity gated), S2 (un-gated) Scalers_%d.dat Delayed nT_Settle
Mott_Sample Mott FADC, S1, S2, TDC Mott_Sample_%d.dat Mott Detector
Mott_SemiInt Mott FADC, S1, S2, TDC Mott_SemiInt_%d.dat Mott Detector
FADC_Int INT FADC, S1, S2 FADC_Int_%d.dat nT_Settle


Mott FADC

 const FADC_ADDR       = 0x680000  # 12 bit fADC MOTT - Slot 7
 const FADCMODE = 1 (Mott_Sample)
 const FADCMODE = 3 (Mott_SemiInt)
 const FADCSLOT_Mott   = 7
 const TRSPLIT         = 0xeb13   # Address of fADC Signal Distribution Module


INT FADC

 const FADC_ADDR       = 0xed0000  # 12 bit fADC Int - Slot 10         
 const FADCMODE = 3 (Int_Int, special)
 const FADCSLOT_PEPPo3 = 10
 const TRSPLIT         = 0xea13   # Address of fADC Signal Distribution Module


TDC

 CAEN v775
 const int V775_ADD    = 0x1190


S1

S2

TID

 A24 Address for TID Module (0x100000 for VME Slot 2)
 const TRIG_ADDR=0x100000