Difference between revisions of "Data Acquisition System"

From Ciswikidb
Jump to navigation Jump to search
Line 23: Line 23:
 
=='''DAQ Software'''==
 
=='''DAQ Software'''==
  
* [[How to run CODA]]
+
* '''[[How to run CODA]]'''
  
* [[Online Monitoring]]
+
* '''[[Online Monitoring]]'''
  
* [[Mott Analysis]]
+
* '''[[Mott Analysis]]'''
  
* [[CODA Summary]]
+
* '''[[CODA Summary]]'''
  
* [[CODA Scripts]]
+
* '''[[CODA Scripts]]'''
  
  

Revision as of 08:31, 12 May 2015

DAQ Hardware

  • Electronic Map of Mott Crates (May 06, 2014):

Media:ElectronicsMap_May062014.pdf

Media:ElectronicsMap_May062014.pptx

  • Cabling of FADC, Scalers, and TDC (February 12, 2014):

Media:Cable_Feb122014.pdf

Media:Cable_Feb122014.pptx

  • DAQ Timing (February 12, 2014):

Media:DAQ_Timing_Feb122014.pdf

Media:DAQ_Timing_Feb122014.pptx

  • Discriminator threshold adjustments (18January2015):

Media:Discriminator_threshold_adjustment.odt

Media:Discriminator_threshold_adjust.ods

DAQ Software


Manuals and References

  • Jefferson Lab Data Acquisition Group CODA Wiki [1]


To-do List

* Repair or replace bad connection at patch panel of detector signals coming from downstairs
* Analysis List:
  1. Add delayed helicity analysis for Mott_Sample and Mott_SemiInt Modes. Delayed analysis is already included for Scalers and PEPPo_Int Modes.
  2. Add BPM Analysis
  3. Modify decoder for the updated Mott_SemiInt mode. Started: /work/idaq/Mott/Analysis/1, Runs: 7642, 7672. Sample: 7673
  4. Update MottOnline
  5. Replace "PEPPo" with "Mott" in scripts, decoder, ... .


* Things to do to speed up the DAQ and reduce deadtime:
  1. Use the new SemiIntFast Mode:
    1. Upgrade the time-of-flight readout to the FADC TDC mode
    2. Upgrade the scalers readout to the FADC Scaler mode
    3. Add Block Readout
  2. Reduce the Mott Trigger rate by rejecting low energy electrons or dump events:
    1. Increase E-detector discriminator thresholds
    2. Veto dump events using beam timing signal