Difference between revisions of "Electrode"

From Ciswikidb
Jump to navigation Jump to search
Line 5: Line 5:
 
* A brand new pure alumina R30 insulator is welded to a 10" CF flange. This flange is the latest design with holes for S&A tooling, and was vacuum fired at 400 C for about 50 hours. Thee flange-ceramic assembly is stored in our HV cabinet (# 9).
 
* A brand new pure alumina R30 insulator is welded to a 10" CF flange. This flange is the latest design with holes for S&A tooling, and was vacuum fired at 400 C for about 50 hours. Thee flange-ceramic assembly is stored in our HV cabinet (# 9).
 
* We should do a leak check of the ceramic assembly.  
 
* We should do a leak check of the ceramic assembly.  
* We should have a second pure alumina R30 insulator welded to one of the two remaining 10" CF vacuum fired flanges
+
* We should have a second pure alumina R30 insulator welded to one of the two remaining 10" CF vacuum fired flanges, as a spare set.
 
* The electrode needs to be put together onto the R30 pure alumina assembly.
 
* The electrode needs to be put together onto the R30 pure alumina assembly.
 
* Use dummy puck and hand over electrode-insulator assembly to S&A
 
* Use dummy puck and hand over electrode-insulator assembly to S&A

Revision as of 09:20, 8 September 2021

  • All of the electrode components are on hand and stored in the cabinet outside TL1337 clean room
  • Ball electrode shell, shed, from Pierce end, and back end (original, no holes) are polished and clean
  • If the GTS HV test show the electrode back end with holes poses no problem with enhanced gradient, we may use that back end style, but it need to be polished. It is in Bubba's office. This is a picture of the assembled GTS electrode showing the back end with the three holes.
Electrode assembly on white R30 back end view zoom.jpg
  • A brand new pure alumina R30 insulator is welded to a 10" CF flange. This flange is the latest design with holes for S&A tooling, and was vacuum fired at 400 C for about 50 hours. Thee flange-ceramic assembly is stored in our HV cabinet (# 9).
  • We should do a leak check of the ceramic assembly.
  • We should have a second pure alumina R30 insulator welded to one of the two remaining 10" CF vacuum fired flanges, as a spare set.
  • The electrode needs to be put together onto the R30 pure alumina assembly.
  • Use dummy puck and hand over electrode-insulator assembly to S&A
  • At this point electrode assembly will be ready for installation in the 18" gun HV chamber


Back to 18" Photogun page