==Startup Tasks==
+
==CEBAF Startup==
 
'''Laser Program'''
 
'''Laser Program'''
 
:A = 50uA @ 125 MHz or 100uA @ 250 MHz
 
:A = 50uA @ 125 MHz or 100uA @ 250 MHz
Line 25: Line 25:
  
 
==GTS==
 
==GTS==
'''SF6'''
+
'''Recovering High Voltage'''
:Bubba repaired leak, pumping now and check
+
:Bubba repaired SF6 leak, pumping now and check
 +
:Test various insulators
 +
:: black = bulk resistivity = shorty R28 (ordered R30, but too little resistivity so too much current draw)
 +
:: white = coated with black = suffer similar resistively too low, but at least constant
 +
:: white + spiral = coated with black but sand-blasted spiral (16 feet path length, so longer length of resistor)
 +
:: tracking on R350 ceramic in SF6 tank possibly due to low SF6 pressure

Revision as of 11:30, 11 February 2015

CEBAF Startup

Laser Program

A = 50uA @ 125 MHz or 100uA @ 250 MHz
B = 499
C = 250

Laser setup

No spare amps, 4-6 weeks from IPG for two replacement amps
Replace 2m (FWHM~1mm) spot lens with 1.5m (FWHM~0.4mm) lens

Phase flip

Make divider box less sensitive to EMI?
Phase monitoring to keep phases between 3 lasers
Analog gain switching at 250 MHz

Change the laser phase

When we change the frequency use 0I04 viewer to check/set phase
Command line EPICS control sufficient now, Mike Johnson still working it
Tomas can provide a ~2ns delay cable
John can DAC control a phase delay ~2ns

To Do

We will learn at separators if we can flip A/D or D/A order
We will decide by summer time a final system configuration

GTS

Recovering High Voltage

Bubba repaired SF6 leak, pumping now and check
Test various insulators
black = bulk resistivity = shorty R28 (ordered R30, but too little resistivity so too much current draw)
white = coated with black = suffer similar resistively too low, but at least constant
white + spiral = coated with black but sand-blasted spiral (16 feet path length, so longer length of resistor)
tracking on R350 ceramic in SF6 tank possibly due to low SF6 pressure