  input file uses beam line G2U which extends from 0.20 m downstream of photocathode to valve upstream of cryounit VBV1M01
+
  #input file uses beam line G2U which extends from 0.20 m downstream of photocathode to valve upstream of cryounit VBV1M01
  G2U element names are entirely nomenclature per ME song sheet to be released
+
  #G2U element names are entirely nomenclature per ME song sheet to be released
  input conditions are presently guess based on CEBAF 100-130 keV gun with typical laser spot size
+
  #input conditions are presently guess based on CEBAF 100-130 keV gun with typical laser spot size
  output file kev.out shows floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891
+
  #output file kev.out shows floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891
 
    
 
    
 
===mev.ele===
 
===mev.ele===
  input file uses beam line U2HD which extends from valve upstream cryounit VBV1M01 to final beam dump IDL5M01
+
  #input file uses beam line U2HD which extends from valve upstream cryounit VBV1M01 to final beam dump IDL5M01
  U2HD element names are presently a mix of generic names and nomenclature, until optics and ME design is refined
+
  #U2HD element names are presently a mix of generic names and nomenclature, until optics and ME design is refined
  input conditions are based on CEBAF emittance measurements at 7 MeV/c just after cryounit
+
  #input conditions are based on CEBAF emittance measurements at 7 MeV/c just after cryounit
  note that cryounit is presently treated as a drift, until dimensions for 2-cell and 7-cell are known
+
  #note that cryounit is presently treated as a drift, until dimensions for 2-cell and 7-cell are known
  output file mev.out shows (continued) floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891
+
  #output file mev.out shows (continued) floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891

Revision as of 17:50, 23 February 2016

This version of UITF is archived at /a/itfdata/uitf/elegant/160223/

kev.ele

#input file uses beam line G2U which extends from 0.20 m downstream of photocathode to valve upstream of cryounit VBV1M01
#G2U element names are entirely nomenclature per ME song sheet to be released
#input conditions are presently guess based on CEBAF 100-130 keV gun with typical laser spot size
#output file kev.out shows floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891
 

mev.ele

#input file uses beam line U2HD which extends from valve upstream cryounit VBV1M01 to final beam dump IDL5M01
#U2HD element names are presently a mix of generic names and nomenclature, until optics and ME design is refined
#input conditions are based on CEBAF emittance measurements at 7 MeV/c just after cryounit
#note that cryounit is presently treated as a drift, until dimensions for 2-cell and 7-cell are known
#output file mev.out shows (continued) floor layout where X=0, Y=1.0668m, Z=0m is placed at "START POINT" on drawing JL0024891