Line 2: Line 2:
  
 
==Chopping Chamber Agenda==
 
==Chopping Chamber Agenda==
* Chopping chamber
+
* Incorporates new FY 92mm ID solenoids
 +
::GPT model puts FY solenoids at Jay's TN center lines -/+ 9.8425 cm, should/can they be different?
 +
::What sort of tolerances should be included in simulations?
 +
* A, B, C slits
 +
:: Use [https://www.lesker.com/newweb/sample_manipulation/linearshifts_lsm-hlsm.cfm linear manipulators]?
 +
:: Use same apertures?
 +
* View screen
 +
::Do we replace chromox screen with a YAG screen?
 +
::Include with markings or fiducials?
 +
* MS/CP apertures
 +
::Do we modify how the MS/CP are inserted/retracted?
 +
::Can we eliminate the CP?
 +
* Vacuum
 +
::Do we replace the honking 120? L/s pump? Yes!
 +
::Replace existing pump with 45 L/sec pump, w/ well located pump out port?
 +
* Shaun drawings...
 +
::[[media:JL0091770 SOLENOID COMPARISONS LEGACY & MFY.pdf]]
 +
::[[media:39200-0033 INJECTOR MODIFICATIONS CHOPPER ASSEMBLY REV- SH1.pdf]]
  
 
==ME Layout Agenda==
 
==ME Layout Agenda==
* Review Danny's layout [[media:200203_layout.pdf]]
+
* Feb 04, 2020 [[media:BEAMLINELAYOUTFEB04.pdf]] edits post modellers meeting (add bpm/cor after Y, and swap bpm/corr by A1
 +
 
 +
* Jan 31, 2020 [[media:200203_layout.pdf]] major revision to address setting up the beam line
 +
 
 +
* First viewer design [[media:YagViewerHole.pdf]]
 +
 
 +
* [https://jeffersonlab-my.sharepoint.com/:x:/g/personal/marcy_jlab_org/ER0n9R8xlVNGpuODOrA5GckB7JihzaNhTu8DHRceCMyVmw?e=aYJLUq BPM overview]  Short [[media:shortBPM.pdf]] and Long [[media:7-52BPM.pdf]] UITF viewers
  
 
* [https://jlabdoc.jlab.org/docushare/dsweb/Get/Document-200405/JLAB-TN-19-025.pdf Jay - Darmstadt quads solution]
 
* [https://jlabdoc.jlab.org/docushare/dsweb/Get/Document-200405/JLAB-TN-19-025.pdf Jay - Darmstadt quads solution]

Latest revision as of 16:21, 5 February 2020

We'll meet at 9am TL-2236 for chopping chamber, then transition into weekly ME meeting

Chopping Chamber Agenda

  • Incorporates new FY 92mm ID solenoids
GPT model puts FY solenoids at Jay's TN center lines -/+ 9.8425 cm, should/can they be different?
What sort of tolerances should be included in simulations?
  • A, B, C slits
Use linear manipulators?
Use same apertures?
  • View screen
Do we replace chromox screen with a YAG screen?
Include with markings or fiducials?
  • MS/CP apertures
Do we modify how the MS/CP are inserted/retracted?
Can we eliminate the CP?
  • Vacuum
Do we replace the honking 120? L/s pump? Yes!
Replace existing pump with 45 L/sec pump, w/ well located pump out port?
  • Shaun drawings...
media:JL0091770 SOLENOID COMPARISONS LEGACY & MFY.pdf
media:39200-0033 INJECTOR MODIFICATIONS CHOPPER ASSEMBLY REV- SH1.pdf

ME Layout Agenda

Quick links