GTS meeting 10 14 19

From Ciswikidb
Revision as of 06:25, 14 October 2019 by Suleiman (talk | contribs) (Created page with "'''Limit voltage to 135kV''' == (1) Status == * Gun assembled with ceramic and blank flange only. Pumping. 4e-8 over 3 days (potential leak) * RF cage complete * Back plate...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Limit voltage to 135kV

(1) Status

  • Gun assembled with ceramic and blank flange only. Pumping. 4e-8 over 3 days (potential leak)
  • RF cage complete
  • Back plate modified and hot deck attached in 'run set-up' (new bar placement an issue - might want to recess the bar)
  • Electrode assembled and snow cleaned ready for installation
  • GTS cleaner

(2) Plans

  • PSS cert
  • Run up Xelera spellman connected to gun to 135kV
  • If corona test good... break vacuum and install electrodes
  • Leak check, Quick HV test, then bake, Kr processing as necessary

To Fix List (to get GTS running):

  • Glassman PSS Chassis (Service request to Omar - Carlos)
  • LCW Chassis (Coleman today or tomorrow)
  • Spellman (needs further investigation)
  • Picoammeter x2? (Pete Francis in hand - sent for fix)
  • Viewers insertion boxes bad

To Check:

  • Magnets (IOC check)
  • Cathode solenoid - power supply

(3) T-Gun Upgrades

To Fix/Modify:

  • DC bias supply - set point fix (John Musson)
  • Software issues (Karl to contact Spellman again)
  • Install new fiber link & check (CW setting - Mark emailed company)
  • Need RF fiber from Karl for reflected power

(4) Housekeeping

  • Remove JLab spellman
  • Sort out the air and nitrogen lines.