GTS meeting 10 31 16

From Ciswikidb
Revision as of 11:45, 31 October 2016 by Chgarcia (talk | contribs) (Created page with "*'''Gun high voltage chamber is under vacuum''' ** The electrode was checked by S&A in their lab, while Bubba was tightening the 10" top CF flange. The center of the spherical...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
  • Gun high voltage chamber is under vacuum
    • The electrode was checked by S&A in their lab, while Bubba was tightening the 10" top CF flange. The center of the spherical electrode is about 1.5 mm high, we left it at that.
    • The gun chamber is now under vacuum, after Phil and Bubba made all vacuum piping connections to the bake pump, replaced the 40 l/s ion pump with a smaller 25 l/s ion pump so that the connector could fit with Riad's magnet in nominal position. Phil also added a right angle valve to the Kr line, and the extractor gauge is mounted on a 1" double side flange to prevent the filament from protruding in the gun chamber (this is bad for high voltage conditioning).
    • the bellows spool piece was completed, Bubba and Phil installed it and now Riad's coil magnet is trapped between the gun and the valve. The chamber was evacuated and preliminary leak checks shows both gate valves are leak tight.
    • GTS gun under vacuum with magnet.jpg
  • Cathode prep chamber is almost ready
    • Mamun and Yan are making great progress, they have added six pucks, one extra Cs effusion source, and even TC to measure the source temperature at its tip and to measure the puck temperature.