Difference between revisions of "GTS meeting 11 13 17"

From Ciswikidb
Jump to navigation Jump to search
Line 1: Line 1:
  
* Old photocathode activated with 5 mm mask
+
* Old photocathode activated with 5 mm mask:[https://logbooks/entry/3492504]
  
  

Revision as of 12:56, 13 November 2017

  • Old photocathode activated with 5 mm mask:[1]


  • Gain switched diode laser at 1064 nm is ready for installation this week (1064 nm, 50 ps Gaussian pulses, efficiency > 30%, 1.8W output, 1497/4=374.25 MHz)


  • Planned measurements:
  1. Commission harps
  2. Map beam emittance vs spot location and laser size
  3. Measure beam magnetization (beam sizes and rotation angle) versus solenoid field from photocathode center and for two laser sizes
  4. Measure lifetime at 5 mA with RF laser and solenoid magnet off/on