Difference between revisions of "GTS meeting 7 23 18"

From Ciswikidb
Jump to navigation Jump to search
 
Line 2: Line 2:
  
 
  Gun = 200 kV
 
  Gun = 200 kV
  laser rms = 0.436 mm
+
  Laser rms = 0.436 mm
  gun solenoid off
+
  Gun Solenoid off
 
  Anode bias = +1000 V
 
  Anode bias = +1000 V
 
  Upstream Ion Collector bias = -44 V
 
  Upstream Ion Collector bias = -44 V

Latest revision as of 09:49, 23 July 2018

  • Measurements Conditions:
Gun = 200 kV
Laser rms = 0.436 mm
Gun Solenoid off
Anode bias = +1000 V
Upstream Ion Collector bias = -44 V
Downstream Ion Collector bias = -92 V (one electrode, second electrode is grounded)


  • Summary of lifetime measurements:
    • 10-min Sb Moly substrate photocathode lifetime: [1]
    • 90-min Sb GaAs substrate photocathode lifetime: [2]
    • 60-min Sb GaAs substrate photocathode lifetime: [3]
    • 30-min Sb GaAs substrate photocathode lifetime: [4]


  • Laser heating measurements:
    • 60-min Sb GaAs substrate photocathode heating
    • 30-min Sb GaAs substrate photocathode heating