Difference between revisions of "GTS meeting 9 14 16"

From Ciswikidb
Jump to navigation Jump to search
Line 1: Line 1:
 
* Cathode Prep Chamber
 
* Cathode Prep Chamber
 
** Mamun and Yan successfully demonstrated that the heat-puck engagement mechanism works.  
 
** Mamun and Yan successfully demonstrated that the heat-puck engagement mechanism works.  
** A spring with 5 leaves was made by the machine shop. Mammon found out that the height of the bend was too much, so he 'flattened' it  bit, making the puck easier to insert and remove.
+
** A spring with 5 leaves was made by the machine shop. Mamun found out that the height of the bend was too much, so he 'flattened' it  bit, making the puck easier to insert and remove.
 
** Measured force to disengage puck: about 3 lbs.
 
** Measured force to disengage puck: about 3 lbs.
 
** Also found that the length of the leaves has to be shorter, Mamun had to add a second 'hose clamp'
 
** Also found that the length of the leaves has to be shorter, Mamun had to add a second 'hose clamp'
Line 22: Line 22:
 
** This Cornell paper shows that ion trapping effects are likely inducing gun (HVPS) trips: [[Media:Cornell-gun-trip-ion-trapping.pdf]]
 
** This Cornell paper shows that ion trapping effects are likely inducing gun (HVPS) trips: [[Media:Cornell-gun-trip-ion-trapping.pdf]]
 
** [http://accelconf.web.cern.ch/accelconf/ERL2013/talks/wg103_talk.pdf Bruce Dunham's talk on high current cathode damage]
 
** [http://accelconf.web.cern.ch/accelconf/ERL2013/talks/wg103_talk.pdf Bruce Dunham's talk on high current cathode damage]
 +
** And Russell's paper on the CsK2Sb BNL cathode high current run: [[Media:PRSTAB by Russell.pdf]]

Revision as of 07:10, 20 September 2016

  • Cathode Prep Chamber
    • Mamun and Yan successfully demonstrated that the heat-puck engagement mechanism works.
    • A spring with 5 leaves was made by the machine shop. Mamun found out that the height of the bend was too much, so he 'flattened' it bit, making the puck easier to insert and remove.
    • Measured force to disengage puck: about 3 lbs.
    • Also found that the length of the leaves has to be shorter, Mamun had to add a second 'hose clamp'
    • Testing under vacuum, found that several heat-cool cycles kept the puck engaged, but after removal form vacuum springs seemed to be more stiff. Mammon thinks it is because the test temp was as high as 300C, which we do not need. Usual photocathode activation is 150-200 C.
    • Mamun is setting up for a temperature calibration using a TC in vacuum.
  • HV Gun chamber
    • Did a test for for the NEGs using the rails and the perforated plate, see picture below.
    • NEG perforated plate mockup front view.jpg
    • The gap between the NEG and the perforated plate is about 1 cm.
    • The rails have been tack welded to the chamber
    • Next is assembling the NEG package inside the gun.
  • Magnetized beam
    • Update from Riad.